Instructions

22
The
150V to 600V models have afour terminal wire clamp output connector:
Phoenix
Contact P/N: FRONT4-H-7.62/4
The
twoleftterminalsare the positive outputs and theother two right terminalsare the negative
output
s.Max. 30A per terminal.
The
connector requirementsare as follows:
1. Wires: AWG18 to AWG10.
2. Tightening torque: 4.4-5.3Lb-inch. (0.5-0.6Nm).
Fig.3-9: Load wires connectiontothe output connector
6. Assemble the enclosure bottom cover to it ’s place, as showninFig.3-10,using screws“C”,
3 places (tightening torque 4.8-5.3 Lb-inch).
7. Slide down the shutter to secure load wires in place, and tighten screws “B”.
Fig.3-10: Enclosure assembly
Load wires
Negative (-)
Output/Return
Positive output (+)
Shutters
Enclosure bottom cover
Enclosuretop cover
B
A1
A2
B
B
C
C
B
Followthe below instructions for connectionofthe load wirestothe power supply:
1. Strip approx.10mm at the end of each of theload wires.
2. Loosen the connector terminal screws.
3. Loosen screws “B” from enclosure bottom cover to release the shutter.
4. Insertstripped wiresinto enclosure bottom cover opening and then to theterminals,
tighten theterminals screws securely(see fig.3-9)
5. Assemblethe enclosuretop cover to the chassisas shown in Fig.3-9,using clamp “A1” and
screw “A2”,tighten screw “A2” (tightening torque:4.8-5.3 Lb-inch).
22