CHAPTER 8 ISOLATED ANALOG PROGRAMMING OPTION
8.1 INTRODUCTION
Isolated Analog Programming is an internal option card for analog programming of the Genesys
power supply series. The option is factory installed and cannot be obtained with GPIB (IEEE)
Interface. Output Voltage and Current Limit can be programmed and readback through optically
isolated signals which are isolated from all other ground references in the power supply.
There are two types of Isolated Analog programming cards:
1. 0-5V/0-10V option (PN: IS510): Using 0-5V or 0-10V signals for programming and readback.
2. 4-20mA option (PN: IS420): Using current signals for programming and readback.
TM
NOTE:
Use 100Kohm minimum input impedance for the monitoring circuits to minimize the readback error.
Programming
Inputs
Output voltage programming accuracy
Output current programming accuracy
Output voltage programming temperature coefficient
Output current programming temperature coefficient
Input impedance
Absolute maximum voltage
Max. voltage between program inputs and supply outputs
Output voltage monitoring accuracy
Output current monitoring accuracy
Output Impedance (see note)
Max. voltage between monitoring outputs and supply outputs
%
%
PPM/ C
PPM/ C
Ohm
Vdc
Vdc
%
%
Ohm
Vdc
o
o
+/-1
+/-1
+/-100
+/-100
1M
0-15
600
+/-1.5
+/-1.5
100
600
Programming
Inputs
Output voltage programming accuracy
Output current programming accuracy
Output voltage programming temperature coefficient
Output current programming temperature coefficient
Input impedance
Absolute maximum input current
Max. voltage between program inputs and supply outputs
Output voltage monitoring accuracy
Output current monitoring accuracy
Maximum load impedance
Max. voltage between monitoring outputs and supply outputs
%
%
PPM/ C
PPM/ C
Ohm
mA
Vdc
%
%
Ohm
Vdc
o
o
+/-1
+/-1
+/-200
+/-200
50
0-30
600
+/-1.5
+/-1.5
500
600
8.2.2 4-20mA option (PN: IS420)
8.2.1 0-5V/0-10V option (PN: IS510)
8.2 SPECIFICATIONS
Monitoring
Outputs
Monitoring
Outputs