Data Sheet

General Specifications Genesys™ 5kW
2.1 INPUT CHARACTERISTICS
GEN 8-600 10-500 16-310 20-250 30 -170 40-125 60-85 80-65 100-50 150-34 200-25 300 -17 400-13 500 -10 600-8.5
1. Input voltage/freq. (*3) VAC
3-Phase, 208V models: 170~265Vac, 47~63Hz
3-Phase, 400V models: 342~460Vac, 47~63Hz
2. Maximum
Input current
at 100% load
3-Phase, 208V models:
A
21 22 22 22 22 22 22 22 22 22 22 22 22 22 22
3-Phase, 400V models: 10.5 11 11 12 11 11 11 11 11 11 11 11 11 11 11
3. Power Factor (Typ) 3-Phase models: 0.94@208/380Vac, rated output power.
4. Efficiency (*4) % 83 84 84 86 86 88 88 88 88 88 88 88 88 88 88
5. Inrush Current (*5) A
3-Phase 208V models: Less than 50A
3-Phase 400V models: Less than 20A
2.2 POWER SUPPLY CONFIGURATION
1. Parallel Operation Up to 4 identical units in master/slave mode
2. Series Operation Up to 2 identical units. with external diodes. 600V Max to Chassis ground
2.3 ENVIRONMENTAL CONDITIONS
1. Operating temp 0~50°C, 100% load.
2. Storage temp -20~85°C
3. Operating humidity 20~90% RH (non-condensing).
4. Storage humidity 10~95% RH (non-condensing).
5. Vibration MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface.
6. Shock Less than 20G , half sine , 11mSec. Unit is unpacked.
7. Altitude
Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
8. RoHS Compliance Complies with the requirements of RoHS directive.
2.4 EMC
1.Applicable Standards:
2.ESD IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV
3.Fast transients IEC1000-4-4. 2KV
4.Surge immunity IEC1000-4-5. 1KV line to line, 2KV line to ground
5.Conducted immunity IEC1000-4-6, 3V
6.Radiated immunity IEC1000-4-3, 3V/m
7.Magnetic field immunity EN61000-4-8, 1A/m
8.Voltage dips EN61000-4-11
9.Conducted emission EN55022A, FCC part 15-A, VCCI-A.
10. Radiated emission EN55022A, FCC part 15-A, VCCI-A.
2.5 SAFETY
1.Applicable standards: UL 60950-1, CSA 22.2 No. 60950-1,IEC 60950-1, EN 60950-1
2.Interface classification
Models with Vout 50V: Output is SELV, all communication/control interfaces (RS232/485, IEEE, Isolated Analog, LAN, Sense, Remote
Programming and Monitoring) are SELV.
Models with 60V Vout 400V: Output is Hazardous, communication/control interfaces: RS232/485, IEEE, Isolated Analog, LAN,
Remote Programing and Monitoring (pins 1-3, pins14-16) are SELV, Sense, Remote Programming and Monitoring (pins 8-13, pins
21-25) are Hazardous.
Models with 400V<Vout 600V: Output is Hazardous, all communication/control interfaces (RS232/485, IEEE, Isolated Analog, LAN,
Sense, Remote Programming and Monitoring) are Hazardous.
3.Withstand voltage
Vout 50V models : Input-Output (SELV): 4242VDC 1min, Input-communication/control (SELV): 4242VDC 1min,
Input-Ground: 2828VDC 1min,
60V<Vout 100V models: Input-Output (Hazardous): 2600VDC 1min, Input-communication/control (SELV):
4242VDC 1min, Output(Hazardous)-SELV: 1900VDC 1min, Output(Hazardous)-Ground: 1200VDC 1min,
Input-Ground: 2828VDC 1min.
100V< Vout 600V models: Input-Output(Hazardous): 3550VDC 1min, Input-communication/control (SELV):
4242VDC 1min, Hazardous. Output-communication/control(SELV): 4242VDC 1min,
Output(Hazardous)-Ground: 2670VDC 1min, Input-Ground: 2828VDC 1min.
3.Insulation resistance More than 100Mohm at 25°C , 70% RH.
2.6 MECHANICAL CONSTRUCTION
1. Cooling Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis; Variable fan speed.
2. Dimensions (WxHxD) W: 423mm, H: 88mm, D: 442.5mm (excluding connectors, encoders, handles, etc.)
3. Weight 13 kg.
4. AC Input connector (with Protective Cover)
Single Phase,230V models, Power Combicon PC 6-16/3-GF-10,16 series, with Strain relief.
3-Phase, 208V & 400V models, Power Combicon PC 6-16/4-GF-10,16 series, with Strain relief.
5.Output connectors 8V to 100V models: Bus-bars (hole Ø 10.5mm). 150V to 600V models: wire clamp connector, Phoenix P/N: FRONT-4-H-7.62
2.7 RELIABILITY SPECS
1. Warranty 5 years.
All specifications subject to change without notice.
5kW | GENESYS | 5