Instructions

2.6 PROGRAMMING AND READBACK (RS232/485, Optional IEEE Interface)
1.Vout programming accuracy
2.Iout programming accuracy (*13)
3.Vout programming resolution
4.Iout programming resolution
5.Vout readback accuracy
6.Iout readback accuracy (*13)
7.Vout readback resolution
8.Iout readback resolution
---
---
---
---
---
---
---
---
0.05% of actual output voltage +0.05% of rated output voltage
0.1% of actual output current +0.2% of rated output current
0.012% of full scale
0.012% of full scale
0.1% of actual output voltage +0.1% of rated output voltage
0.1% of actual output current +0.3% of rated output current
0.012% of full scale
0.012% of full scale
2.7 PROTECTIVE FUNCTIONS
1.Foldback protection
2.Over-voltage protection
3.Over-voltage trip point
4.Output under voltage limit
5.Over temperature protection
V
8
15
2010
30
40
60
80
100
150
300
600
---
---
---
---
V
Output shut-down when power supply change from CV to CC User presetable.
Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port command.
Preset by front panel or communication port. Prevents from adjusting Vout below limit.
User selectable, latched or non latched.
0.5~10
0.5~12
2~36
1~24
1~18
2~44
5~66
5~165
5~110
5~88
5~330
5~660
2.8 FRONT PANEL
---
---
---
---
---
---
---
---
---
---
---
---
---
Vout/Iout manual adjust by separate encoders (coarse and fine adjustment).
OVP/UVL manual adjust by Vout. Adjust encoder.
Address selection by Voltage Adjust encoder. No of addresses:31.
Go to local control.
Output on/off
AC on/off
Front panel Lock
Foldback control
Baud rate selection: 1200, 2400, 4800, 9600 and 19200.
Re-start modes (automatic restart, safe mode).
Vout: 4 digits, accuracy: 0.5% of rated output voltage +/-1count.
Iout: 4 digits, accuracy: 0.5% of rated output current +/-1count.
VOLTAGE, CURRENT, ALARM, FINE, PREVIEW, FOLDBACK, LOCAL, OUTPUT ON, FRONT PANEL LOCK.
1.Control functions
2.Display
3.Indications
2.9 ENVIRONMENTAL CONDITIONS
1.Operating temperature
2.Storage temperature
3.Operating humidity
4.Storage humidity
5.Altitude
---
---
%
%
---
0~50 C, 100% load.
-20~85 C
20~90% RH (no condensation).
10~95% RH (no condensation).
Maximum 3000m. Derate output current by 2%/100m above 2000m. Alternatively, derate maximum
ambient temperature by 1 C/100m above 2000m.
o
o
O
2.10 MECHANICAL
1.Cooling
2.Weight
3.Dimensions (WxHxD)
4.Vibration
5.Shock
---
Kg
mm
---
---
Forced air cooling by internal fans.
Less than 13Kg.
W: 423, H: 88, D: 442.5 (Refer to Outline drawing).
MIL-810F, method 514.5
Less than 20G, half sine, 11mS. Unit is unpacked.
UL60950-1 listed, EN60950-1. Vout<40V: Output is SELV, IEEE/Isolated Analog are SELV.
60<Vout<400V: Output is hazardous, IEEE/Isolated Analog are SELV.
400<Vout<600V: Output is hazardous, IEEE/Isolated Analog are not SELV.
EN55024
Vout< 40V models: Input-Outputs (SELV): 4242VDC 1min, Input-Ground: 2828VDC 1min,
40V<Vout<100V models: Input-Haz. Output: 2600VDC 1min, Input-SELV: 4242VDC 1 min, Hazard.
1900VDC 1min, Hazard. Output-Ground: 1200VDC 1 min, Input-Ground: 2828VDC 1min.
100V<Vout<600V models: Input-Haz. Output: 4000VDC 1min, Input-SELV: 4242VDC 1min, Hazard.
Output-SELV: 3550VDC 1min, Hazard. Output-Ground: 2670VDC 1min, Input-Ground: 2828VDC 1min.
More than 100Mohm at 25 C, 70%RH.
EN55022A, FCC part 15-A, VCCI-A
EN55022A, FCC part 15-A, VCCI-A
o
2.11 SAFETY/EMC
2.Withstand voltage
3.Insulation resistance
4.Conducted emmision
5.Radiated emission
1.Applicable standards: Safety
---
---
---
---
---
---
---
EMC
10