Instructions

56
NOTE:
The power supply can accept values higher by 5% than the table values, however it
is not recommended to program the power supply over the rated values.
7.7.7 Status control commands
Refer to section 7-8 for definition of the registers.
Command
#
Description
1
STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
Table 7-5: OVP programming range
Table 7-6: UVL programming range
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
8
10
15
20
30
40
60
80
100
150
300
600
0.5
0.5
1.0
1.0
2.0
2.0.
5.0
5.0
5.0
5.0
5.0
5.0
10.0
12.0
18.0
24.0
36.0
44.0
66.0
88.0
110.0
165.0
330.0
660.0
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
8
10
15
20
30
40
60
80
100
150
300
600
0
0
0
0
0
0
0
0
0
0
0
0
7.60
9.50
14.3
19.0
28.5
38.0
57.0
76.0
95.0
142
285
570
MV<actual (measured) voltage>
PV<programmed (set) voltage>
MC<actual (measured) current>
PC<programmed (set) current>
SR<status register, 2-digit hex>
FR<fault register, 2-digit hex>
Example response: MV(45.201),PV(45),MC(4.3257),PC(10),SR(30),FR(00)
Reads Fault Conditional Register. Return 2-digit hex.
Set Fault Enable Register using 2-digit hex.
Reads Fault Enable Register. Returns 2-digit hex.
Reads Fault Event Register. Returns 2-digit hex. Clears bits of Fault Event Register.
Reads Status Conditional Register. Returns 2-digit hex.
Sets Status Enable Register using 2-digit hex.
Reads Status Enable Register. Returns 2-digit hex.
Reads Status Event register. Returns 2-digit hex. Clears bits of Status Event register.
2
3
4
5
6
7
8
9
FLT?
FENA
FENA?
FEVE?
STAT?
SENA
SENA?
SEVE?
Minimum
(A)
Model
Maximum
(A)
GEN8-400
GEN10-330
GEN15-220
GEN20-165
GEN30-110
GEN40-85
GEN60-55
GEN80-42
GEN100-33
GEN150-22
GEN300-11
GEN600-5.5
000.00
000.00
000.00
00.00
00.00
00.00
00.000
00.000
00.000
00.000
0.000
0.000
400.00
330.00
220.00
165.00
110.00
85.00
55.000
42.000
33.000
22.000
11.000
5.500
Current programming range
Table 7-4: