Datasheet

!
!
!
!
PV voltage (Nominal Input Voltage)
Output Voltage Linearity
5.5V
6V 5V
Nominal
Vout
0
60%
3V
110%
120%
Output Voltage
80%
4V
24 & 48V Model
48V Model
12~36V Model
12 & 36V Model
!
!
Output Voltage Derating
100% 83%
Nominal
Vout
0
110%
120%
90%
Load Current
Output Voltage
80%
60%
24 & 48V Model
48V Model
12
~
36V Model
12 & 36V Model
GWS250 Series
3
Output Derating Curve GWS250
-
25 0 25 50 75 100
Ta (°C)
Load (%)
120
1
00
8
0
60
40
20
0
GWS250 Output Voltage External Control (PV)
T
Mounting Options GWS250 - For other mounting versions please refer to Instruction Manual
7
0
50
Output voltage external control function is available. Output voltage can be varied by applying an external voltage (3-6V) to ‘PV’ and ‘COM’ terminals at
signal connector CN1
Please consider the following characteristics.
Notes:
For 12V & 36V output model, limit output voltage variation range at 60% - 110%. At PV voltage variation 3V - 5.5V
For 24V output model, limit output voltage variation range at 60% - 120%. At PV voltage variation 3V - 6V
For 48V output model, limit output voltage variation range at 80% - 120%. At PV voltage variation 4V - 6V
Options
Suffix Description
/T OTP auto recovery after unit cools down
/RL Remote ON/OFF reverse logic (Active High)
/
BAT Battery charging for 24V (21 -29V/8.8A) & 48V (42-58V/4.4A) only
/P Power up to 350W with system airflow of 20cfm minimum and
air blowing in from opposite side of input/output connectors
/
L Without cover
N
otes:
GWS250-XX/YYYYYYYYYYYYY where XX can be 12, 24, 36, or 48
Y option can be any combination of P, L, RL, CO, CO2, T, BAT, or blank
MOQs apply to Option models
Please contact your local TDK-Lambda sales office for details.
Provide clearance 15mm or more on top of power supply
Mounting Method
1 This is convection cooling type power supply. In consideration of the heat radiation and safety, please keep a distance of more than 15mm between the power supply and the peripheral
parts. When lining up multiple units, please make sure to place them 5mm or more apart from each other
2 Maximum allowable penetration of mounting screws into the power-supply is 5mm
3 Recommended torque for mounting screws (M4): 1.27 Nm (13.0 kgf.cm)
Air Flow
Connection Method
Output Voltage Linearity
Output Voltage Derating
T
Sheet
Metal