200 SERIES SPECIFICATIONS
PROGRAMMING AND READBACK (RS232/485,USB, Optional: IEEE, LAN)
1.Voutprogrammingaccuracy --- 0.05%ofratedoutputvoltage
2.Ioutprogrammingaccuracy(*13) --- 0.1%ofactual+0.1%ofratedoutputcurrent
3.Voutprogrammingresolution --- 0.012%offullscale
4.Ioutprogrammingresolution --- 0.012%offullscale
5.Voutreadbackaccuracy --- 0.05%ofratedoutputvoltage
6.Ioutreadbackaccuracy(*13) --- 0.1%ofactual+0.3%ofratedoutputcurrent
7.Voutreadbackresolution --- 0.012%offullscale
8.Ioutreadbackresolution --- 0.012%offullscale
INPUT CHARACTERISTICS
Z 10-20 20-10 36-6 60-3.5 100-2
1.Inputvoltage/freq.(*3) --- 85~265Vaccontinuous,47~63Hz,singlephase
2.MaximumInputcurrent100/200VAC(*4)(*18) --- 2.65/1.31 2.62/1.29 2.76/1.37 2.69/1.33 2.55/1.26
3.PowerFactor(Typ) --- >0.99at100Vac,>0.98at200Vac,100%load
4.Efficiency(Typ)100/200VAC(*4)(*18) % 76/77.5 77/79 79/80.5 79/80.5 79/81
5.Inrushcurrent100/200VAC(*5) --- Lessthan15A/30A
ENVIRONMENTAL CONDITIONS
1.Operatingtemperature --- 0~50°C,100%load.
2.Storagetemperature --- -20~85°C
3.Operatinghumidity % 20~90%RH(nocondensation).
4.Storagehumidity % 10~95%RH(nocondensation).
5.Altitude ---
Maximum3000m.Derateambienttempabove2000m.
Operating:Maximumambienttemperature,From2000mupto3000mAmbienttemperature40°C.
SAFETY/EMC
1.Applicablestandards:
Safety ---
UL61010-1,EN61010-1,IEC61010-1.DesigntomeetUL60950-1,EN60950-1
10V≤Vout≤60V:Output,J1,J2,J3,J4,USB,LAN,IEEE/ISOLATEDAnalogareNonHazardous
Vout=100V:Output,J1,J2areHazardousJ3,J4,USB,IEEE/ISOLATEDAnalog,LANareNonHazardous
EMC --- IEC/EN61326-1(BuilttomeetEN55022/EN55024)
2.Withstandvoltage ---
10≤Vout≤36Vmodels:Input-Output&J1,J2,J3,J4,USB,LAN/IEEE/ISOLATEDANALOG:4242VDC/1min;Input-Ground:2828VDC/1min.
Output&J1,J2,J3,J4,USB,LAN/IEEE/ISOLATEDANALOG-Ground:707VDC/1min.
60V,100Vmodels:Input-Output&J1,J2:4242VDC/1min;Input-J3,J4,USB,LAN/IEEE/ISOLATEDAnalog:4242VDC/1min;Input-Ground:2828VDC/1min.
Output&J1,J2-J3,J4,USB,LAN/IEEE/ISOLATEDANALOG:1910VDC/1min;Output&J1,J2-Ground:1380VDC/1min.
J3,J4,USB/LAN/IEEE/ISOLATEDANALOG-Ground:707VDC/1min;
3.Insulationresistance --- Morethan100Mohmat25°C,70%RH.
4.Conductedemission --- IEC/EN61326-1IndustrialLocation-B,FCCpart15-B,VCCI-B
5.Radiatedemission --- IEC/EN61326-1IndustrialLocation-A,FCCpart15-A,VCCI-A
MECHANICAL
1.Cooling --- Forcedaircoolingbyinternalfan.
2.Weight
STANDARD Kg
Lessthan1.9Kg.
Lessthan2.4Kg.WidebodywithIsolatedanalogorBindingpostorIEEE.
WIDEBODY Kg
3.Dimensions(WxHxD)
STANDARD mm
H:83,W:70,D:350(excludingbusbars,handles…).(RefertoOutlinedrawing).
H:83,W:105,D:350(excludingbusbars,handles…).(RefertoOutlinedrawing).
WIDEBODY mm
4.Vibration --- Accordingto:IEC60068-2-64
5.Shock --- Lessthan20G,halfsine,11mS.Unitisunpacked.Accordingto:IEC60068-2-27
NOTES:
*1:Minimumvoltageisguaranteedtomaximum0.1%ofratedoutputvoltage.
*2:Minimumcurrentisguaranteedtomaximum0.2%ofratedoutputcurrent.
*3:Forcaseswhereconformancetovarioussafetystandards(UL,IEC,etc…)isrequired,tobedescribedas100-240Vac(50/60Hz).
*4:Ta=25°Cwithratedoutputpower.
*5:NotincludingEMIfilterinrushcurrent,lessthan0.2mSecatcoldstartTa=25°C
*6:At85~132Vacor170~265VAC,constantload.
*7:FromNo-LoadtoFull-Load,constantinputvoltage.MeasuredatthesensingpointinRemoteSense.
*8:MeasuredwithJEITARC-9131A(1:1)probe.
*9:From10%to90%or90%to10%ofRatedOutputVoltage,withratedresistiveload.
*10:From90%to10%ofRatedOutputVoltage.
*11:Forloadvoltagechange,equaltotheunitvoltagerating,constantinputvoltage.
*12:For10Vmodeltherippleismeasuredat2Vtoratedoutputvoltageandratedoutputcurrent.Forothermodels,therippleismeasuredat10~100%
ofratedoutputvoltageandratedoutputcurrent.
*13:TheConstantCurrentprogramming,readbackandmonitoringaccuracydonotincludethewarm-upandLoadregulationthermaldrift.
*14:MeasuredwithJEITARC-9131A(1:1)probe.
*15:ForcaseswherethetimeintervalbetweeneachdownprogrammingislongerthanTd(timedelay).
*16:ForcaseswherethetimeintervalbetweeneachdownprogrammingisshorterthanTd(timedelay).
*17:TdtypicalMinimumtimebetweenconsecutivedownprogrammingcycles.
*18:PSwithLan,IEEE,modelsdecreaseefficiencyby0.5%andincreaseinputcurrentby0.5%.
PSwithIsolatedanalogoptiondecreasesefficiencyby1.5%andincreasesinputcurrentby1.5%.
*19:Atratedoutputpower.
*20:ForParalleloperationmorethan2units5%oftotaloutputcurrentisrequierd.