Series Programmable DC Power Supplies 200W/400W/600W/800W in 2U Built-in USB, RS-232 & RS-485 Interface Optional Interface: Compliant LAN IEEE488.
Features Include: • • • • • • • • • • • • • • • • • • • • • • • High Power Density 200W/400W/600W/800W in 2U: 3.5 Inch (89mm) height Wide Range Input (85-265Vac continuous) Active Power Factor Correction (0.
Front Panel Description 1. 2. 3. 4. 5. 6. 7. AC ON/OFF Switch Air Intake allows zero stacking for maximum system flexibility and power density.* Reliable encoder controls Output Voltage and power supply setting. Volt Display shows Output Voltage and directly displays and power supply settings. Reliable encoder controls Output Current, and power supply setting. Current Display shows Output Current and power supply setting.
Rear Panel Description 1. 2. 3. 4. 5. 6. 7. Connector allows (Non-isolated) Analog Program and Monitor and other functions. Remote/Local Output Voltage Sense Connections. Signal Connector RS-232/RS-485 INPUT Remote Serial Programming. + RS-485 OUTPUT to other Z Power Supplies. USB Interface Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99 typical) AC Input Connector: IEC320 -C16. 8. Exhaust air exits at the back.
Power Benchtop Parallel and Series Configurations Benchtop Power Supply Parallel operation - Master/Slave: Active current sharing allows up to six identical units to be connected in an auto-parallel configuration for six times the output power. In Advanced Parallel Master/Slave Mode, total current is programmed and reported by the Master, Up to six supplies act as one. Series operation Up to two units may be connected in series to increase the output voltage or to provide bipolar output.
Applications + Z series power supplies have been designed to meet the demands of a wide variety of applications. Test and Measurement Built-in Last-Setting memory based on Flash Memory no battery or capacitor backup. Simplifies test design and requirements. Built-in RS-232/RS-485 gives maximum system flexibility along with 0-5V and 0-10V, selectable analog programming. Wide range of available inputs allows testing of many different devices.
Options: (200W/400W/600W/800W) Front Panel Output Jacks Up to 60V Output Module P/N: Z_ _ - _ _ - L Up to 24A Output Current via Front Panel Jacks Z+ Assemblies Dual Output Housing (for 105mm) 200W/400W/600W/800W Triple Output Housing (for 70mm) 200W/400W/600W/800W P/N: Z-NL200 (same p/n for both Dual & Triple Output Housing) 19" Rack Mounted to 4.
Programming Options (Factory Installed) Digital Programming via IEEE Interface • • • • • • • • P/N: IEEE IEEE 488.2 SCPI Compliant Program Voltage • Program Current Measure Voltage • Measure Current Over Voltage setting and shutdown • Current Foldback shutdown Error and Status Messages Multi-Drop Allows IEEE Master to control up to 31 slaves over RS-485 daisy-chain Only the Master needs be equipped with IEEE Interface Isolated Analog Programming Four Channels to Program and Monitor Voltage and Current.
Power Supply Identification / Accessories How to order Z 10 - Series Name 40- Output Voltage Output Current (0~10V) (0~40A) Factory option USB Interface built-in Standard RS-232/RS-485 Interface built-in Standard GPIB Interface Voltage Programming Isolated Analog Interface Current Programming Isolated Analog Interface Class C) LAN Interface (Complies with Front Panel Output Jacks (60V or 24A max) Model Z10-20 Z10-40 Z10-60 Z10-72 Z20-10 Z20-20 Z20-30 Z20-40 Z36-6 Z36-12 Z36-18 Z36-24 Z60-3.
+ Z 200 SERIES SPECIFICATIONS MODEL 1. Rated output voltage(*1) 2. Rated output current (*2) 3. Rated output power CONSTANT VOLTAGE MODE 1. Max. Line regulation (*6) 2. Max. Load regulation (*7) 3. Ripple and noise (p-p, 20MHz) (*8) 4. Ripple r.m.s. 5Hz~1MHz 5. Temperature coefficient 6. Temperature stability 7. Warm-up drift 8. Remote sense compensation/wire 9. Up-prog. Response time, 0~Vomax.(*9) 10. Down-prog.
+ Z 200 SERIES SPECIFICATIONS 1. Vout programming accuracy 2. Iout programming accuracy (*13) 3. Vout programming resolution 4. Iout programming resolution 5. Vout readback accuracy 6. Iout readback accuracy (*13) 7. Vout readback resolution 8. Iout readback resolution ----------------- INPUT CHARACTERISTICS 1. Input voltage/freq. (*3) 2. Maximum Input current 100/200VAC (*4) (*18) 3. Power Factor (Typ) 4. Efficiency (Typ) 100/200VAC (*4) (*18) 5.
+ Z 400 SERIES SPECIFICATIONS MODEL 1. Rated output voltage(*1) 2. Rated output current (*2) 3. Rated output power Z V A W 10-40 10 40 400 20-20 20 20 400 Z ----mV mV PPM/°C ----V mS 10-40 20-20 Z ------mA PPM/°C ----- 10-40 20-20 PROTECTIVE FUNCTIONS Z 10-40 1. Foldback protection --- CONSTANT VOLTAGE MODE 1. Max. Line regulation (*6) 2. Max. Load regulation (*7) 3. Ripple and noise (p-p, 20MHz) (*8) 4. Ripple r.m.s. 5Hz~1MHz 5. Temperature coefficient 6. Temperature stability 7.
+ Z 400 SERIES SPECIFICATIONS 1. Vout programming accuracy 2. Iout programming accuracy (*13) 3. Vout programming resolution 4. Iout programming resolution 5. Vout readback accuracy 6. Iout readback accuracy (*13) 7. Vout readback resolution 8. Iout readback resolution PROGRAMMING AND READBACK (RS232/485,USB, Optional: IEEE(*20), LAN) --0.05% of rated output voltage --0.1% of actual +0.1% of rated output current --0.012% of full scale --0.012% of full scale --0.05% of rated output voltage --0.
+ Z 600 SERIES SPECIFICATIONS MODEL 1. Rated output voltage(*1) 2. Rated output current (*2) 3. Rated output power CONSTANT VOLTAGE MODE 1. Max. Line regulation (*6) 2. Max. Load regulation (*7) 3. Ripple and noise (p-p, 20MHz) (*8) 4. Ripple r.m.s. 5Hz~1MHz 5. Temperature coefficient 6. Temperature stability 7. Warm-up drift 8. Remote sense compensation/wire 9. Up-prog. Response time, 0~Vomax.(*9) 10. Down-prog.
+ Z 600 SERIES SPECIFICATIONS PROGRAMMING AND READBACK (RS232/485,USB, Optional: IEEE(*19), LAN) --0.05% of rated output voltage --0.1% of actual +0.1% of rated output current --0.012% of full scale --0.012% of full scale --0.05% of rated output voltage --0.1% of actual +0.3% of rated output current --0.012% of full scale --0.012% of full scale 1. Vout programming accuracy 2. Iout programming accuracy (*13) 3. Vout programming resolution 4. Iout programming resolution 5. Vout readback accuracy 6.
+ Z 800 SERIES SPECIFICATIONS MODEL 1. Rated output voltage(*1) Vin ≥ 100Vac, Ta ≤ 50°C 2. Rated output 85Vac ≤ Vin < 100Vac, Ta ≤ 40°C current (*2)(*21) 85Vac ≤ Vin < 100Vac, 40°C < Ta ≤ 50°C Vin ≥ 100Vac, Ta ≤ 50°C 3. Rated output 85Vac ≤ Vin < 100Vac, Ta ≤ 40°C power 85Vac ≤ Vin < 100Vac, 40°C < Ta ≤ 50°C Z V A A A W W W 10-72 10 72 72 66 720 720 660 20-40 20 40 40 36 800 800 720 CONSTANT VOLTAGE MODE 1. Max. Line regulation (*6) 2. Max. Load regulation (*7) 3. Ripple and noise (p-p, 20MHz) (*8) 4.
+ Z 800 SERIES SPECIFICATIONS INPUT CHARACTERISTICS 1. Input voltage/freq. (*3) 2. Maximum Input current 100/200VAC (*4) 3. Power Factor (Typ) 4. Efficiency (Typ) 100/200VAC (*4) 5. Inrush current (*5) Z ------% --- ENVIRONMENTAL CONDITIONS 1. Operating temperature 2. Storage temperature 3. Operating humidity 4. Storage humidity ----% % --- 5. Altitude Rated output current Z A A 10-72 9.00/4.45 81/83 20-40 36-24 60-14 85~265Vac continuous, 47~63Hz, single phase 9.65/4.75 10.30/5.10 10.00/4.95 0.
Outline Drawings Z+200W/400W/600W/800W
Outline Drawings Z+200W/400W/600W/800W Front Panel Output Jacks 19" Rack Housing for Z+200W/400W/600W/800W
UK TDK-Lambda UK Ltd. Kingsley Avenue Ilfracombe, Devon EX 34 8ES United Kingdom Tel: +44-1271-856666 Fax: +44-1271-864894 E-mail: powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com FRANCE TDK-Lambda France SAS ZAC des Delaches BP 1077 - Gometz le Chatel 91940 LES ULIS Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 E-mail: france@fr.tdk-lambda.com www.fr.tdk-lambda.com GERMANY TDK-Lambda Germany GmbH Karl-Bold-Str.40, D-77855 Achern, Germany Tel: +49-7841-666-0 Fax: +49-7841-500-0 E-mail: info.