Information

15
Z
+
600 SERIES SPECIFICATIONS
PROGRAMMING AND READBACK (RS232/485,USB, Optional: IEEE(*19), LAN)
1.Voutprogrammingaccuracy --- 0.05%ofratedoutputvoltage
2.Ioutprogrammingaccuracy(*13) --- 0.1%ofactual+0.1%ofratedoutputcurrent
3.Voutprogrammingresolution --- 0.012%offullscale
4.Ioutprogrammingresolution --- 0.012%offullscale
5.Voutreadbackaccuracy --- 0.05%ofratedoutputvoltage
6.Ioutreadbackaccuracy(*13) --- 0.1%ofactual+0.3%ofratedoutputcurrent
7.Voutreadbackresolution --- 0.012%offullscale
8.Ioutreadbackresolution --- 0.012%offullscale
INPUT CHARACTERISTICS
Z
10-60 20-30 36-18 60-10 100-6
1.Inputvoltage/freq.(*3) --- 85~265Vaccontinuous,47~63Hz,singlephase
2.MaximumInputcurrent100/200VAC(*4) --- 7.48/3.69 7.22/3.56 7.70/3.80 7.13/3.52 7.13/3.52
3.PowerFactor(Typ) --- 0.99at100,0.98at200Vac,100%load
4.Efficiency(Typ)100/200VAC(*4) % 81/83 84/86 85/87 85/87 85/87
5.Inrushcurrent(*5) --- Lessthan30A
ENVIRONMENTAL CONDITIONS
1.Operatingtemperature --- 0~50°C,100%load.
2.Storagetemperature --- -20~85°C
3.Operatinghumidity % 20~90%RH(nocondensation).
4.Storagehumidity % 10~95%RH(nocondensation).
5.Altitude ---
Maximum3000m.Derateambienttempabove2000m.
Operating:Maximumambienttemperature,From2000mupto3000mAmbienttemperature40°C.
SAFETY/EMC
1.Applicablestandards:
Safety ---
UL61010-1,EN61010-1,IEC61010-1.DesigntomeetUL60950-1,EN60950-1
10V≤Vout≤60V:Output,J1,J2,J3,J4,USB,LAN,IEEE/ISOLATEDAnalogareNonHazardous
Vout=100V:Output,J1,J2areHazardousJ3,J4,USB,IEEE/ISOLATEDAnalog,LANareNonHazardous
EMC --- IEC/EN61326-1(BuilttomeetEN55022/EN55024)
2.Withstandvoltage ---
10Vout36Vmodels:Input-Output&J1,J2,J3,J4,USB,LAN/IEEE/ISOLATEDANALOG:4242VDC/1min;Input-
Ground:2828VDC/1min.
Output&J1,J2,J3,J4,USB,LAN/IEEE/ISOLATEDANALOG-Ground:707VDC/1min.
60V,100Vmodels:Input-Output&J1,J2:4242VDC/1min;Input-J3,J4,USB,LAN/IEEE/ISOLATEDAnalog:
4242VDC/1min;Input-Ground:2828VDC/1min.
Output&J1,J2-J3,J4,USB,LAN/IEEE/ISOLATEDANALOG:1910VDC/1min;Output&J1,J2-Ground:
1380VDC/1min.
J3,J4,USB/LAN/IEEE/ISOLATEDANALOG-Ground:707VDC/1min;
3.Insulationresistance --- Morethan100Mohmat25°C,70%RH.
4.Conductedemission --- IEC/EN61326-1IndustrialLocation-B,FCCpart15-B,VCCI-B
5.Radiatedemission --- IEC/EN61326-1IndustrialLocation-A,FCCpart15-A,VCCI-A
MECHANICAL
1.Cooling --- Forcedaircoolingbyinternalfan.
2.Weight
STANDARD Kg
Lessthan2.1Kg.
Lessthan2.6Kg.WidebodywithIsolatedanalogorBindingpostorIEEE.
WIDEBODY Kg
3.Dimensions(WxHxD)
STANDARD mm
H:83,W:70,D:350(excludingbusbars,handles…).(RefertoOutlinedrawing)
H:83,W:105,D:350(excludingbusbars,handles…).(RefertoOutlinedrawing)
WIDEBODY mm
4.Vibration --- Accordingto:IEC60068-2-64
5.Shock --- Lessthan20G,halfsine,11mS.Unitisunpacked.Accordingto:IEC60068-2-27
NOTES:
*1:Minimumvoltageisguaranteedtomaximum0.1%ofratedoutputvoltage.
*2:Minimumcurrentisguaranteedtomaximum0.2%ofratedoutputcurrent.
*3:Forcaseswhereconformancetovarioussafetystandards(UL,IEC,etc…)isrequired,tobedescribedas100-240Vac(50/60Hz).
*4:Ta=25Cwithratedoutputpower.
*5:NotincludingEMIfilterinrushcurrent,lessthan0.2mSec.
*6:At85~132Vacor170~265VAC,constantload.
*7:FromNo-LoadtoFull-Load,constantinputvoltage.MeasuredatthesensingpointinRemoteSense.
*8:MeasuredwithJEITARC-9131A(1:1)probe.
*9:From10%to90%or90%to10%ofRatedoutputVoltage,withratedresistiveload.
*10:From90%to10%ofRatedoutputVoltage.
*11:Forloadvoltagechange,equaltotheunitvoltagerating,constantinputvoltage.
*12:For10Vmodeltherippleismeasuredat2Vtoratedoutputvoltageandratedoutputcurrent.Forothermodels,therippleismeasured
at10~100%
ofratedoutputvoltageandratedoutputcurrent.
*13:TheConstantCurrentprogramming,readbackandmonitoringaccuracydonotincludethewarm-upandLoadregulationthermaldrift.
*14:MeasuredwithJEITARC-9131A(1:1)probe.
*15:ForcaseswherethetimeintervalbetweeneachdownprogrammingislongerthanTd(timedelay).
*16:ForcaseswherethetimeintervalbetweeneachdownprogrammingisshorterthanTd(timedelay).
*17:TdtypicalMinimumtimebetweenconsecutivedownprogrammingcycles.
*18:Atratedoutputpower.
*19:Max.ambienttemperatureforusingIEEEis45°C
*20:ForParalleloperationmorethan2units5%oftotaloutputcurrentisrequired.