7.12.2 Instrument Subsystem
The subsystem programs one or more power supplies. <NR1> from 1 to 31.
INSTrument:COUPle
SCPI Command Syntax INSTrument:COUPle <CRD>
GEN Command Syntax None
Parameters ALL|NONE
INSTrument:NSELect
SCPI Command Syntax INSTrument:NSELect <NRf>
GEN Command Syntax ADR n (single address)
Examples INSTrument:NSELect 6
Query Syntax INSTrument:NSELect?
7.12.3 Voltage Subsystem
VOLTage
Sets the output voltage value in Volts. The range of voltage values are described in Table 7-5. The
maximum number of characters is 12.
SCPI Command Syntax [SOURce]:VOLTage[:LEVel] [:IMMediate][:AMPLitude] <NRf+>
GEN Command Syntax PV < NRf+> PV?
Default Suffix V
*RST Value 0
Examples :VOLT 500 MV VOLT:LEV 234.56789
Query Syntax
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?
VOLTage? MAX VOLTage? MIN
Returned Parameters
<NR3> VOLT? returns the present programmed voltage level.
VOLT? MAX and VOLT? MIN returns the maximum and minimum programmable
voltage levels.
VOLTage:MODE
This command selects FIX, LIST, WAVE subsystems control over the power supply output voltage.
SCPI Command Syntax [SOURce]:VOLTage:MODE <CRD>
GEN Command Syntax None
Parameters NONE | FIXed | LIST | WAVE
*RST Value NONE
Examples VOLT:MODE LIST VOLT:MODE FIX
Query Syntax [SOURce]:VOLTage:MODE?
Returned Parameters NONE | FIX | LIST | WAVE