Instructions

107
CURRent:MODE
This command selects FIX, LIST, WAVE subsystems control over the power supply output current.
SCPI Command Syntax [SOURce]:CURRent:MODE <CRD>
GEN Command Syntax None
Parameters NONE | FIXed | LIST | WAVE
*RST Value NONE
Examples CURR:MODE LIST CURR:MODE FIX
Query Syntax [SOURce]:CURRent:MODE?
Returned Parameters NONE | FIX | LIST | WAVE
CURRent:TRIGger
Programs the pending triggered current level of the power supply. The pending triggered current
level is a stored value that is transferred to the output terminals when a trigger occurs.
SCPI Command Syntax [SOURce]:CURRent[:LEVel]:TRIGger[:AMPLitude] <NRf+>
GEN Command Syntax None
Default Suffix A
Examples CURR:TRIG 3200 MA CURR:LEV:TRIG 3.2
Query Syntax [SOURce]:CURRent[LEVel]:TRIGger [:AMPLitude]?
Returned Parameters
<NR3> CURR:TRIG? returns the presently programmed triggered level. If no
triggered level is programmed, the CURR level is returned.
NOTE:
CURR:MODE LIST and WAVE are an implied ABORt command. Only the last sent command can be
accepted as WAVE or LIST. Previous mode reverts to NONE.
7.12.5 Measure Subsystem
This subsystem reads the actual voltage and current. The power is a result of multiplying voltage
and current measurements.
MEASure:CURRent?
Reads the measured output current. Returns a 5 digit string.
SCPI Command Syntax MEASure:CURRent?
GEN Command Syntax MC?
Parameters None
Default Suffix A
Returned Parameters <NR3>