Instructions

108
MEASure:VOLTage?
Reads the measured output voltage. Returns a 5 digit string.
SCPI Command Syntax MEASure:VOLTage?
GEN Command Syntax MV?
Parameters None
Default Suffix V
Returned Parameters <NR3>
MEASure:POWer?
Reads the measured output power. Returns a 5 digit string.
SCPI Command Syntax MEASure:POWer?
GEN Command Syntax MP?
Parameters None
Default Suffix W
Returned Parameters <NR3>
7.12.6 DISPlay Subsystem
DISPlay:STATe
Turns front panel voltage and Current display toggle On or Off.
SCPI Command Syntax DISPlay[:WINDow]:STATe <bool>
GEN Command Syntax none
Parameters 0|OFF 1|ON
Examples DISP:STAT 1 DISP:STAT OFF
Query Syntax DISPlay[:WINDow]:STAT?
Returned Parameters 0 |1
DISPlay:FLASh
Makes front panel voltage and Current displays flash.
SCPI Command Syntax DISPlay[:WINDow]:FLASh <bool>
GEN Command Syntax none
Parameters 0|OFF 1|ON
Examples DISP:FLASh 1 DISP:FLASh OFF