Subsystem Commands
SCPI Command Description GEN Command
ABORt Aborts the triggered action <NC>
DISPlay
[:WINDow]:STATe <bool> Display ON/OFF <NC>
[:WINDow]:FLASh <bool> Display Flash <NC>
GLOBal
:CURRent
:[AMPLitude] <NRf+> Set the output current for all power supplies GPC
:VOLTage
:[AMPLitude] <NRf+> Set the output voltage for all power supplies GPV
:OUTPut:STATe <bool> Enables/disables the all power supplies output GOUT
*RCL {1|2|3|4} Recall setting for all power supplies GRCL
*RST Reset all power supplies GRST
*SAV {1|2|3|4} Save settings for all power supplies GSAV
INITiate
[:IMMediate] Trigger initiate <NC>
:CONTinuous <bool> Enable/disable continuously trigger <NC>
INSTrument
:COUPle ALL|NONE Couple for all Z
+
power supplies <NC>
:NSELect <NRf> Select the power supply for communication ADR
MEASure
:CURRent[:DC]? Returns the measured output current MC?
:VOLTage[:DC]? Returns the measured output voltage MV?
:POWer[:DC]? Returns the measured output power MP?
OUTPut
[:STATe] <Bool> Enables/disable the supply output OUT[?]
:PON
[:STATe] <bool> Programs the Power-ON state AST[?]
:PROTection
:CLEar Resets latched protection
:FOLDback
[:MODE] OFF|CC|CV Set operation protection mode FLD[?]
:DELay <NRf+> Set protection delay FBD[?]
:ILC
:MODE <bool> Enables/disable analog output ON/OFF control RIE[?]
:TTLTrg
:MODE OFF|FSTR|TRIG Set output trigger mode <NC>