Instructions

124
8.5 Trigger
Subsystem
Level
Display Function Level Display Parameter Level Display Description
Trigger Setting
triG
INIT
iniT
INIT
init
Initialization
(Refer to command INIT)
ready for trigger.
TRIG
TriG
Continue
ConT
ENA
EnA
refer to command
INIT:CONT
DIS
dis
Trigger
IN (input
trigger)
tr
.
In
BUS (via Software
or front Panel),
Bs
refer to command
TRIG:SOUR
EXT (Analog)
ET
Trigger delay
tr
.
d
0-65sec
0
.
100
refer to command
TRIG:DELAY.
Fine and Course modes
Trigger OUT
tr
.
O
OFF
OFF
refer to command
OUTP:TTLT:MODE
Trigger
TriG
Function Strobe
F
.
STR
Programming
rOG
LOAD List or
Wave data
Od
L1…L4
2
Refer to commands
LIST:LOAD and
WAVE:LOAD
COUNter (set
repeat time)
CON
1…9999
12
(Refer to LIST:COUN
and WAVE:COUN) allow
course and fine setting
STEP setting
ste
ONCE
ONCE
(Refer to LIST:STEP and
WAVE:STEP)
AUTO
ATO
ABORt
execution
bor
YES
YES
(Refer to command
ABORt)
Table 8-1: Trigger and Programming front panel menu
NOTE:
At AC power ON the display shows last selected program list but dosen’t load it from memory.
NOTE:
If during program selection L1-L4, display shows ”ERR message then program memory is empty or
power supply is in initiated state. Select ”ABORt to EXIT from initiate state.
8.5.1 Input Trigger
Trigger source can be set via:
BUS - Command (Refer to section 7.11 *TRG, 7.12 TRIGger) or Front Panel.
EXT - Rear panel connector J3-8 (Refer to section 4.3.2).
Input Trigger source setting via Front Panel:
1. Press MENU button. MENU (green) LED illuminates. ”set” message appears on the Voltage
display.
2. Rotate Voltage encoder until ”t ri G message appears on Voltage display.
3. Press Voltage encoder. ”init” message appears on Voltage display.
4. Rotate Voltage encoder until ”TR
.
In ” message appears. Press Voltage encoder.
5. TR
.
In ” message appears on Voltage Display and ”EH t” or ”BS” messages appear on Current
display. Rotate to scroll list and press Current encoder to select.