CAUTION:
To prevent damage to the unit, do not program the output voltage and current to higher than the
power supply rating.
10.4 Setup and Operating Instructions
CAUTION:
To prevent damage to the unit, do not program the output voltage and current to higher
than the power supply rating.
10.4.1 Setting Up Power Supply for 0-5/0-10V Isolated Programming and Monitoring
Perform the following procedure to configure the power supply:
1. Turn the power supply AC power switch to Off.
2. Short pins J1-1 to J1-7, and turn AC power switch to On.
3. Press MENU button. MENU (GREEN) LED illuminates. ”Set” message appears on Voltage display.
4. Press Voltage encoder. ” Ot” message appears on Voltage Display and ”Cv RR” appears on
the Current display.
5. Press Voltage encoder to select programming of the Output Voltage, or press Current encoder
to select programming of the Output Current.
6. The selected function appears on the Voltage display. Parameter ”F
.
N” or ”E
.
O” or ”E
.
res
appears on the Current display.
7. Rotate and press the Current encoder to select ”E
.
O”.
10. Ot” message appears on Voltage Display and ”Cv RR” appears on the Current display.
11. Rotate Voltage encoder untilrNG” appears on Voltage display. Press on the Voltage encoder.
12.rANG” appears on Voltage display and ”5” (5V) or ”10” (10V) appears on Current display.
13. Rotate and press the Current encoder to select the desired programming Voltage range.
14. Press MENU button twice to return display to it’s previous state. MENU LED turns OFF
15. Connect the programming sources to the mating plug of the Isolated Programming connector.
Observe for correct polarity of the voltage source.
16. Set the programming sources to the desired levels and turn the power supply ON.
NOTE:
J1-1 and J1-7 must be shorted together with a jumper.
10.4.2 Setting Up Power Supply for 4-20mA Isolated Programming and Monitoring
The set up procedure of 4-20mA Isolated Programming and Monitoring is the same as section
10.4.1 except ”rANG setting. ”rANG setting must be set to ”10 (10V).