2.5 Supplemental Characteristics
The supplemental characteristics give typical but non-warranted performance characteristics.
The supplemental characteristics are useful in assessing applications for the power supply. Several kinds of supplemental characteristics are listed below.
1. Evaluation Data: Typical performance of the power supply.
2. Reliability Data: Reliability performance of the power supply.
3. IEC61000 Data: Performance of the power supply under IEC61000 test conditions.
4. EMI Data: Typical EMI (conducted and radiated) performance of the power supply.
The supplemental characteristics data is held in each TDK-Lambda sales and service facility. For further details please contact the TDK-Lambda office near you.
Z
+
800 Series Specifications
INPUT CHARACTERISTICS Z 10-72 20-40 36-24 60-14 100-8
1. Input voltage/freq. (*3) --- 85~265Vac continuous, 47~63Hz, single phase
2. Maximum Input current 100/200VAC (*4) --- 9.00/4.45 9.65/4.75 10.30/5.10 10.00/4.95 9.50/4.7
3. Power Factor (Typ) --- 0.99 at 100Vac, 100% load / 0.98 at 200Vac, 100% load
4. Efficiency (Typ) 100/200VAC (*4) % 81/83 84/86 85/87 85/87 85/87
5. Inrush current (*5) --- Less than 30A
ENVIRONMENTAL CONDITIONS
1. Operating temperature --- 0~50°C, 100% load.
2. Storage temperature --- -20~85°C
3. Operating humidity % 20~90% RH (no condensation).
4. Storage humidity % 10~95% RH (no condensation).
5. Altitude
---
Maximum 3000m.
From 2000m up to 3000m, max. Ambient temperature 40°C and rated output current according to the table below:
Z 10-72 20-40 36-24 60-14 100-8
Rated output current
A 72 40 24 14 8
A 66 36 20 12.5 7.5
SAFETY/EMC
1. Applicable standards:
Safety ---
UL61010-1, EN61010-1, IEC61010-1. Design to meet UL60950-1, EN60950-1
10V≤Vout≤60V: Output,J1,J2,J3,J4,USB,LAN,IEEE/ISOLATED Analog are Non Hazardous
Vout=100V:Output,J1,J2 are Hazardous J3,J4,USB, IEEE/ISOLATED Analog ,LAN are Non Hazardous
EMC --- IEC/EN61326-1 (Built to meet EN55022/EN55024)
2. Withstand voltage ---
10≤Vout≤36V models: Input-Output&J1,J2,J3,J4,USB,LAN/IEEE/ISOLATED ANALOG: 4242VDC/1min; Input-Ground: 2828VDC/1min.
Output&J1,J2,J3,J4,USB,LAN/IEEE/ISOLATED ANALOG-Ground: 707VDC/1min.
60V,100V models: Input-Output&J1,J2: 4242VDC/1min; Input-J3,J4,USB,LAN/IEEE/ISOLATED Analog: 4242VDC/1min; Input-Ground: 2828VDC/1min.
Output&J1,J2- J3,J4,USB,LAN/IEEE/ISOLATED ANALOG :1910VDC/1min; Output&J1,J2-Ground: 1380VDC/1min.
J3, J4, USB/LAN/IEEE/ISOLATED ANALOG - Ground: 707VDC/1min;
3. Insulation resistance --- More than 100Mohm at 25°C, 70%RH.
4. Conducted emission --- IEC/EN61326-1 Industrial Location - B, FCC part 15-B, VCCI-B
5. Radiated emission --- IEC/EN61326-1 Industrial Location - A, FCC part 15-A, VCCI-A
MECHANICAL
1. Cooling --- Forced air cooling by internal fan
2. Weight
STANDARD Kg Less than 2.1Kg.
WIDE BODY Kg Less than 2.6Kg. Wide body with Isolated analog or Binding post or IEEE
3. Dimensions (WxHxD)
STANDARD mm H: 83, W: 70, D: 350 (excluding bus bars, handles…). (Refer to Outline drawing)
WIDE BODY mm H: 83, W: 105, D: 350 (excluding bus bars, handles…). (Refer to Outline drawing)
4. Vibration --- According to: IEC60068-2-64
5. Shock --- Less than 20G, half sine, 11mS. Unit is unpacked. According to: IEC60068-2-27
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 100-240Vac (50/60Hz).
*4: Ta=25°C with rated output power.
*5: Not including EMI filter inrush current, less than 0.2mSec.
*6: At 85~132Vac or 170~265VAC, constant load.
*7: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
*8: Measured with JEITA RC-9131A (1:1) probe.
*9: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated resistive load.
*10: From 90% to 10% of Rated Output Voltage.
*11: For load voltage change, equal to the unit voltage rating, constant input voltage.
*12: For 10V model the ripple is measured at 2V to rated output voltage and rated output current. For other models, the ripple is measured at 10~100%
of rated output voltage and rated output current.
*13: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
*14: Measured with JEITA RC-9131A (1:1) probe.
*15: For cases where the time interval between each down programming is longer than Td (time delay).
*16: For cases where the time interval between each down programming is shorter than Td (Time delay).
*17: Td typical Minimum time between consecutive down programming cycles.
*18: At rated output power.
*19: Max. ambient temperature for using IEEE is 45°C
*20: For Parallel operation more than 2 units 5% of toatal output current is requierd.
*21: Refer to Fig.2-1 below
Fig. 2-1: Z
+
800 Rated Output Current Vs. Line Voltage and Ambient Temperature