Instructions

39
1 Local (-) sense
2 (-) Sense
3 (+) Sense
4 Local (+) sense
Fig.3-3: Sense connector default connection
Plug P/N: IPD1-02-D-K
(SAMTEC)
2. Ensure that the protection of output bus-bars or of output connector is mounted and properly
assembled for power supplies when the output voltage exceed 42.4VDC.
3. Connect the unit to an AC source as described in section 3.7.
4. Connect a DVM with appropriate cables for the rated voltage to the output terminals.
5. Turn the front panel AC power switch to On.
6. When power supply is turned ON the display shows ”” and all LEDs illuminate momentarily.
The power supply operating status is then displayed.
3.7.2 AC Input Cord
Refer to section 1.3.4 for details of the AC input cords recommended.
WARNING:
The AC input cord plug is the disconnect device of the power supply. The plug must be readily
identifiable and accessible to the user. The AC input cord must be no longer than 3m.
WARNUNG:
Das Netzstromkabel dient zur Trennung des Netzgerätes vom Netzstrom. Der Stecker muss für den
Benutzer leicht erkennbar und jederzeit zugänglich sein. Das Netzstromkabel darf nicht länger sein
als drei Meter.
3.8 Turn-On Checkout Procedure
3.8.1 General
The following procedure ensures that the power supply is operational and may be used as a basic
incoming inspection check.
3.8.2 Prior to Operation
1. Ensure that the power supply is configured to the default setting:
AC On/Off switch at Off position.
Sense connector : Configured to Local Sense as shown in Fig.3-3: