5.9 Parameter Setting Memory
Power Supply has four memory configuration modes:
Subsystem
Level
Display
Function
Level
Display
Parameter
Level
Display Description
Memory
MEMo
SAVE
SAE
1…4
1
...
4
Save setting in non violate memory
RECALL
REC
1…4
1
...
4
Recall setting in non violate memory
RST
RST
YES
es
Reset setting
FRST
F
.
rst
YES
es
Set factory default setting
Table 5-6: Parameter Setting Memory
5.9.1 Default Setting
For factory default parameters refer to Table 5-7.
1. Press MENU button. MENU (green) LED illuminates. ”set” message appears on the Voltage
display.
2. Rotate Voltage encoder until ”MEMO” message appears on Voltage display.
3. Press Voltage encoder. ”se” message appears on Voltage Display.
4. Rotate Voltage encoder until ”F
.
rs t” message appears on Voltage display.
5.
Press Voltage encoder. ”F
.
rs t” message appears on Voltage Display, and ”es” appears on Current
display .
6. Press the Current encoder ”HOd” Message appears on the display for 1sec. The display blinks
once and returns to previous level.
7. Press MENU button twice to return display to previous state, MENU LED turns OFF.
NOTE:
No response for FRST command. After this command the power supply loses communication because
of communication setting change.
5.9.2 Reset
For Reset parameters refer to Table 5-7.
1. Press MENU button. MENU (green) LED illuminates. ”set” message appears on the Voltage
display.
2. Rotate Voltage encoder until ”MEMO” message appears on Voltage display.
3. Press Voltage encoder. ”se” message appears on Voltage Display.
4. Rotate Voltage encoder until ”rst” message appears on Voltage display.
5. Press Voltage encoder. ”rs t” message appears on Voltage Display. ”es” appears on the
Current display .
6. Press the Current encoder, display blinks and returns to previous level.
7. Press MENU button twice to return display to previous state, MENU LED turns OFF.
5.9.3 Last Setting Memory
Memory stores last set parameters when AC switch is turned off.
For last set parameters refer to Table 5-7.