7.8.8 Status Commands
Refer to section 9.3.1, 9.3.2 for Register definitions.
# Command Description
1 STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage> PC<programmed (set) current>
PV<programmed (set) voltage> SR<status register, 4-digit hex>
MC<actual (measured) current> FR<fault register, 4-digit hex>
Example response: MV(45.201),PV(45.000),MC(4.3257),PC(10),SR(0030),FR(0000)
2 FLT? Reads Fault Conditional Register. Return 4-digit hex.
3 FENA Set Fault Enable Register using 4-digit hex.
4 FENA? Reads Fault Enable Register. Returns 4-digit hex.
5 FEVE? Reads Fault Event Register. Returns 4-digit hex. Clears bits of Fault Event Register.
6 STAT? Reads Status Conditional Register. Returns 4-digit hex.
7 SENA Sets Status Enable Register using 4-digit hex.
8 SENA? Reads Status Enable Register. Returns 4-digit hex.
9 SEVE? Reads Status Event register. Returns 4-digit hex. Clears bits of Status Event register.
7.8.7 Auxiliary Commands
SOP Sets SO polarity ”SO 1/ON” –Positive (default), ”SO 0/OFF”-Negative
SOP? Returns the SO polarity
RIE Remote Interlock (Inhibit) enable. ”RIE 1/ON”-Enable, ”RIE 0/OFF”-Disable
RIE? Returns Interlock enable status. ”ON” –interlock enable, ”OFF”-interlock disable.
FRST
Factory reset command. This command cover *RST command and additional settings. Sets factory
default. This command breaks communication. Refer to Table
5-7.
MP? Reads the actual output power. Returns 5 digit string.
REL1 Set auxiliary programmed pin state J3-1. ”REL1 1/ON”- High, REL1 0/OFF”- Low
REL1? Response auxiliary programmed pin state J3-1.
REL2 Set auxiliary programmed pin state J3-6, ”REL2 1/ON”- High, REL2 0/OFF”- Low
REL2? Response auxiliary programmed pin state J3-6