Instructions

Page 13 of 16 ZPSA Series, 17211 issue 3 April 2013
Product HANDBOOK
ZPSA40/60 Series
Special Safety Instructions:
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA60950-1 (<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Environmental Specifications:
Description Operation Storage
Use Indoor -
C - +70°C (derating at 2.5%/°C from 50°C)
Temperature
(For ZPSA40/60 -3,-5,-9)
C - +70°C derating at 2.5%/°C from 40°C)
-20°C - +85°C
Humidity 10 - 95% RH, non-condensing 10 - 95% RH, non-
condensing
Altitude 2000M 2000M
Orientation See Fig 1 ALL
Material Group IIIb
Pollution Degree 2
IP Protection Class IPX0
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains to earth: 1.5kVAC
Primary mains circuits to secondary: 3kVAC, 4142VDC
Output to earth isolation 500VDC
.Safety Approvals:
UL/cUL60950-1 (2
nd
Edition)
IEC / EN60950-1(2
nd
Edition)
CE marking when applied to any ZPSA40/60-xx product indicates compliance with the Low Voltage Directive
(2006/95/EC) in that it complies with EN60950-1 (2
nd
Edition).
Fusing: Internal fuses (F1): Single fuse in the L line, T2.2AL, 250V,
Input Connection
ACN – Neutral ACL – Live
Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal
ZPSA40/60 –xx