Instructions

Page 14 of 16 ZPSA Series, 17211 issue 3 April 2013
Product HANDBOOK
ZPSA40/60 Series
Input Parameters:
Standard 60950-1
Rated input voltage 100-240 VAC
Input voltage range 90 – 264VAC
Input frequency range 47 – 63Hz
Maximum input current
115/240VAC
130mA/
0.70mA
270mA/
0.130mA
400mA/
0.200mA
Inrush current 30A max at 230VAC
Class of Equipment II
Overvoltage Category II
Output Parameters:
Model Vout (V) Output
current (A)
Model Vout (V) Output
current (A)
3.3 6.0 3.3 8.0
5 6.0 5 8.0
9 4.45 9 6.67
12 3.34 12 5.0
15 2.67 15 4.0
24 1.67 24 2.5
28 1.43 28 2.14
36 1.11 36 1.67
40W
48 0.834
60W
48 1.25
Output connector mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal
Adjusting output voltage beyond the set value stated may cause overvoltage protection (OVP) to operate,
whereby the output will latch off. To reset for normal operation simply adjust the potentiometer to reduce the
output voltage to within its range and cycle the input off then on.
All outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if
the total output voltage exceeds 60Vdc
If the total voltage of outputs connected in series exceed the 60Vdc SELV limit then all outputs must be
considered non-SELV.
Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to
service engineers making inadvertent contact with the output terminals in the end equipment.
Cooling for unit
The ZPSA40/60 series are convection cooled, recommended installation
Equipment top