Datasheet

Table Of Contents
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lead spacing 7.5 mm 10 mm 15 mm 22.5 mm 27.5 mm
V
R
V
RMS
V DC V AC dV/dt in V/µs
63 40 120 60
100 63 150 75 50 50 25
250 160 200 150 100 100 50
400 200 275 175 125 125 60
420 200 60
630 350 320 150
630 400 320
1000 500 360
k
0
values
Lead spacing 7.5 mm 10 mm 15 mm 22.5 mm 27.5 mm
V
R
V
RMS
V DC V AC k
0
in V
2
/µs
63 40 15 000 7500
100 63 30 000 15 000 10 000 10 000 5 000
250 160 100 000 75 000 50 000 50 000 25 000
400 200 220 000 140 000 100 000 100 000 50 000
420 200 50 000
630 350 400 000 190 000
630 400 400 000
1000 500 720 000
B32560 ... B32564
General purpose (stacked) SilverCap
TM
Page 13 of 32Please read Cautions and warnings and
Important notes at the end of this document.