Data Sheet

Reliability data
Test Standard Test conditions R
25
/R
25
Electrical endurance,
cycling
IEC 60738-1 Room temperature, I
Smax
; V
max
Number of cycles: 500 000
< 25%
Electrical endurance,
constant
IEC 60738-1 Storage at V
max
/T
op,max
(V
max
)
Test duration: 1000 h
< 25%
Damp heat IEC 60738-1 Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
< 10%
Rapid change
of temperature
IEC 60738-1 T
1
= T
op,min
(0 V), T
2
= T
op,max
(0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, Test Na
< 25%
Vibration IEC 60738-1 Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, Test Fc
< 5%
Sensors
Motor protection, single sensors M1100
Page 4 of 11Please read Cautions and warnings and
Important notes at the end of this document.