Information

94
Catalog 82181 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 2-07 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-8706-080-208
Mini-Universal MATE-N-LOK 2 Connectors (Continued)
AMP
Soft Shell
Pin and Socket Connectors
Mini-Universal MATE-N-LOK 2 Connectors
.163 [4.14] Centerline
High Density
Performance
Characteristics (Continued)
Maximum Current—Maximum
current rating of Mini-Universal
MATE-N-LOK 2 connectors is limited by
the maximum operating temperature of
the housings which is 105°C (gold) or
85°C (tin) including the temperature rise
of the contacts which is a maximum of
30°C. There are several variables which
have a direct effect on this maximum
current-carrying capability for a given
connector and must be considered for
each application. These variables are:
Wire Size—Larger diameter wire will
carry more current since it has less
internal resistance to current flow and
thus generates less heat. Longer wire
lengths also enhance current-carrying
capabilities since the wire conducts heat
away from the connector.
Connector Size—In general, the more
circuits in a connector, the less current
can be carried.
Ambient Temperature—The higher
the ambient temperature, the less current
can be carried in any given connector.
Printed Wiring Board Conductor
Size—The finished trace conductor
width and thickness should be maxi-
mized to allow for the greatest current-
carrying capacity and heat dissipation.
Contacts
Pin diameter .039 [0.99]
Material
Brass
Stock Thickness .010 [0.25]
These contacts can be used in either
Mini-Universal MATE-N-LOK 2 Plug or
Cap housings only.
Related Product Data
Product Specifications
108-1693 Mini-Universal MATE-N-LOK 2
Connectors
108-1694 Mini-Universal MATE-N-LOK 2
Headers
Application Specification
114-1111 Mini-Universal MATE-N-LOK 2
Connectors
Performance Characteristics
pages 93-94
Housings — pages 95-96
Technical Documents pages 93
and 199-200
Current Rating Verification for 30°C Maximum Temperature Rise 100% Energized
Pin Socket
Contact Part Numbers
HDM Hand
Wire Size
Ins. Dia.
Finish
Pin Socket
Applicator
Tool
Range
Range
Strip Loose Strip Loose
Part No. Part No.
AWG [mm
2
]
Form Piece Form Piece
30 -26 .035 -.050
Pre-tin 794216-1 794224-1 794217-1 794225-1
567418-1
2
567418-2
2
90717-2
[.05 -.12] .889 -1.27
Duplex
1
1-794216-0 1-794224-0 1-794217-0 1-794225-0
567418-3
2
26 -22 .047 -.069
Pre-tin 794218-1 794226-1 794219-1 794227-1
567066-3
3
567066-4
3
91529-1
[.12 -.3] 1.19 -1.75
Duplex
1
1-794218-0 1-794226-0 1-794219-0 1-794227-0
567066-5
3
22 -18 .059 -.094
Pre-tin 794220-1 794228-1 794221-1 794229-1
680854-1
2
680854-2
2
91522-1
[.3 -.8] 1.50 -2.39
Duplex
1
1-794220-0 1-794228-0 1-794221-0 1-794229-0
680854-3
2
20-16 .079-.126
Pre-tin 794222-1 794230-1 794223-1 794231-1
680582-2
2
[.5-1.2] 2.01-3.20
Duplex
1
1-794222-0 1-794230-0 1-794223-0 1-794231-0
680582-3
2
91594-1
1
Duplex Finish Plated with .000030 [.000762] min. gold in mating area and .000100 [.00254] min. tin in
crimping area over .000050 [.00127] min. nickel underplate on entire contact.
2
HDM Applicator part number ending in -1 is used on AMPOMATOR CLS Machine with T or G Terminators, -2 is used
on AMP-O-LECTRIC Model K Machine, -3 is used on AMP-O-ELECTRIC Model G Machine.
3
HDM Applicator part number ending in -3 is used on AMPOMATOR CLS Machine with T or G Terminators, -4 is used
on AMP-O-LECTRIC Model K Machine, -5 is used on AMP-O-LECTRIC Model G Machine.
See pages 201-204 for further information.
Note: All part numbers are RoHS Compliant.
Not to be used with Mini-Universal MATE-N-LOK Connectors
.775
[19.69]
.775
[19.69]
10.5
Amps
max.
6.75
Amps
max.
Current Rating (Amperes)
0
5
10
15
105100908070605040-35-45-55 11075
30 30 25 20 15 10 5 0
Temperature Rise (Degrees C)
Current is limited above 75° C so
as not to exceed 105° C (maximum
operating temperature) once the
t–rise is added to the ambient
18 AWG
24 AWG
Ambient Temperature (Degrees C)
7.5
Amps
max.
5
Amps
max.
Current Rating (Amperes)
0
5
10
15
105100908070605040-35-45-55 11075
30 30 25 20 15 10 5 0
Temperature Rise (Degrees C)
Current is limited above 75° C so
as not to exceed 105° C (maximum
operating temperature) once the
t–rise is added to the ambient
18 AWG
24 AWG
Ambient Temperature (Degrees C)
6 Circuit Connector (Wire-to-Wire)
2 Circuit Connector (Wire-to-Wire)