Datasheet

01-2015, Rev. 0115
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
SCHRACK
General Purpose Relays
PCB Relays
Miniature Power PCB RYII & RYII Reflow Solderable
n
1 pole 8A, 1 form C (CO) or 1 form A (NO) or 1 form B (NC) contact
n
Low component height 12.3mm
n
5kV/8mm coil-contact
n
Reinforced insulation (protection class II)
n
Pinnings: 3.2mm and 5mm
n
Reflow-solderable version
n
Especially suitable for resistive and inductive loads on
form A (NO) and form B (NC) contacts
n
Plastic materials according to IEC 60335-1 (domestic appliances)
Typical applications
heating control, interface technology, domestic appliances, timers,
temperature control
Approvals
VDE Cert. No. 40009639, UL E214025
Technical data of approved types on request
Contact Data
Contact arrangement 1 form C (CO) or
1 form A (NO) or
1 form B (NC)
Rated voltage 250VAC
Max. switching voltage 400VAC
Rated current 8A
Breaking capacity max. 2000VA
Contact material AgNi0.15, AgSnO
2
Frequency of operation, with/without load 6/1200min
-1
Operate/release time max. 9/5ms
Bounce time max., form A/form B 6/10ms
Contact ratings
Type Contact Load Cycles
IEC61810
RY531 A (NO) 8A, 250VAC, 70°C 100x10
3
RY211 A (NO) 8A, 250VAC, 70°C 75x10
3
RY211 B (NC) 8A, 250VAC, 70°C 50x10
3
UL508
RY211 A/B (NO/NC) 10A, 250VAC, general purpose, 70°C 30x10
3
RY211 A (NO) 1/2hp, 240VAC, 85°C 30x10
3
RY211 A/B (NO/NC) B300, 70°C 6x10
3
EN60730-1
RY211 A/B (NO/NC) 6(4)A, 250VAC, 85°C 100x10
3
RY211 A (NO) 8(4)A, 250VAC, 75°C 100x10
3
Mechanical endurance, DC coil 30x10
6
operations
Coil Data
Coil voltage range 5 to 60VDC
Operative range, IEC 61810 2
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
005 5 3.5 0.5 112 223
006 6 4.2 0.6 162 222
009 9 6.3 0.9 320 253
012 12 8.4 1.2 627 230
024 24 16.8 2.4 2350 245
048 48 33.6 4.8 9391 245
060 60 42.0 6.0 14000 257
All figures are given for coil without pre-energization, at ambient temperature +23°C
Other coil voltages on request
Insulation Data
Initial dielectric strength
between open contacts 1000V
rms
between contact and coil 5000V
rms
Clearance/creepage
between contact and coil ≥8/8mm
Material group of insulation parts IIIa
Tracking index of relay base PTI250
reflow-solderable version PTI175
F0142-E
Z