Test Description Requirement Procedure
ENVIRONMENTAL
Thermal Shock (b) (c) Dielectric withstanding voltage;
insulation resistance.
Subject mated connectors
to 5 cycles between -55°
and 105°C;
Test Specification 109-22.
Industrial Mixed Flowing Gas Shielding effectiveness final
Subject mated connectors to
environmental class III for 10 days;
Test Specification 109-85-3.
Figure 1 (end)
3.6. Connector and Hardware Qualification and Requalification Tests and Sequences
Test Group (a)
1 2 3
Test or Examination
Test Sequence (b)
Examination of Product 1 1 1
Dielectric Withstanding Voltage 2, 8
Shielding Effectiveness 3, 9 2, 4 2, 4
Vibration 4
Physical Shock 5
Cable Pullout 6
Circular Jacket cable Flexing 7
Thermal Shock 3
Industrial Mixed Flowing Gas 3
Figure 2
NOTE
(a) Maximum rated current that can be carried by this product is limited by
maximum operating temperature of housings, which is 30°C.Variables
which shall be considered for each application are: wire size, connector
size, contact material, and ambient temperature.
(b) Shall remain mated and show no evidence of damage, cracking or
chipping.
(c) The temperature range of this test must be adjusted as necessary to
assure that the temperatures of the cable assemblies are exposed to
shall not exceed the temperature rating of either the cable or the
connector.
NOTE
(a) See Para 4.1.A.