Information

108-40005
Test Description Requirem ent Procedure
Contact retention force. Contacts shall nor dislodge from
housing when subjected to a
minimum force of 44.5 N [10 lbf].
EIA-364-29.
Apply specified to contacts in an
axial direction and hold for 6
seconds.
Contact engaging force. 2.2 N [8 ozf] m axim um per contact. EIA-364-37.
Measure force necessary to insert
gage A to a depth of 5.6 m m [.220
in].
See Figure 6.
Contact separating force. 0.208 N [.75 ozf] m inim um per
contact.
EIA-364-37.
Size 2 tim es using gage A. Insert
gage B to a depth of 5.6 m m [.220
in] and m easure force necessary to
separate gage B.
See Figure 6.
Crim p tensile. W ire Size Crim p Tensile
(AW G) (N [lbf] m inimum )
18 120.1 [27]
20 89 [20]
22 53.4 [12]
24 35.6 [8]
26 20 [4.5]
28 12 [2.7]
EIA-364-8.
Determ ine crim p tensile at a
maxim um rate of 25.4 m m [1 in] per
minute.
ENVIRONMENTAL
Therm al shock. See Note. EIA-364-32, Test Condition VII.
Subject unmated specim ens to 5
cycles between -55 and 105°C.
Hum idity/tem perature cycling. See Note. EIA-364-31, Method III with cold
shock.
Subject mated specim ens to 10
cycles (10 days) between 25 and
65°C at 80 to 100% RH.
Tem perature life. See Note. EIA-364-17, Method A, Test
Condition 4, Test Tim e Condition C.
Subject mated specim ens to 105°C
for 500 hours.
Mixed flowing gas. See Note. EIA-364-65, Class IIIA (4 gas).
Subject mated specim ens to
environm ental Class IIIA for 20
days.
Shall meet visual requirements, show no physical damage, and meet requirements of additional
NOTE
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
2.
Figure 1 (end)
Rev F 4 of 10