Datasheet

114--16017
Rev L12 of 12
6. VISUAL AID
The illustration below shows a typical application of Mini--Universal MATE--N--LOK connectors. This illustration
should be used by production personnel to ensure a correctly applied product. Appli cations which DO NOT
appear correct shoul d be inspected using the information in the preceding pages of this specificati on and in the
instructional material shipped w ith the product or tooling.
FIGURE 10. VISUAL AID
WI RE STRANDS MUST BE
VISIBLE ANYWHERE I N
THIS AREA
LOCKING LANCES MUST
NOT BE NOT DEFORM ED
WI RE STRANDS AND INSULATION MUST
BOTH BE VISIBLE ANYWHERE IN THIS AREA
FRONT AND REAR BELLMOUTHS
MUST B E VISIBLE
CUTOFF TAB MUST BE VISIBLE
STANDOFFS MUST BE
VISUALLY SEATED ON
PC BOARD
SOLDER FILLET MUST
BE FORMED EVEN LY
AROUND TINES
CABLE TIE MUST BE MINIMUM
DISTANCE OF 76.2 [3.00] FROM
WIRE END OF HOUSING
LOCKING LATCHES
AND TABS MUST BE
SECURELY FASTENED
LOCKING LATCHES
AND TABS MUST BE
SECURELY FASTENED
FREE - HANGING APPLICATION
PC BOARD APPLICATION
CRIMPED CONTACT
CONTACT STOP MUST NOT
BE CRIMPED OR DEFORMED