Rev L 3 of 12
3.2. Contact Crimp Requirements
A. Carrier Cutoff
There shall be no burrs on the cutoff tab. The carrier cutoff tab length shall not exceed the dimension
giveninFigure2.
B. Crimp Height
The insulation barrel shall be formed around but not cut into the wire insulation. The wire barrel and
insul ation barrel crimp height and wi dth is given in Figure 2.
The applied crimp dimension (within the function range of the product) is dependent on the termination tooling being
used. Refer to the documentation (applicator logs and instruction sheets) supplied with the termination tooling for the
applied crimp height.
C. Contact Stop
The contact stop must not be crimped. Any deformation to the contact stop will compromise the insertion
depth of the contact in the contact cavity of the housing.
D. Front and Rear Bellmouths
The front bellmouth shall be visibl e. The rear bellmouth shall conform to the dimensions given in Figure 2.
E. Wire Location
The end of the wire shall be flush with the end of the wire barrel or protrude no more than the dimension
giveninFigure2.
F. Locking Lances
The locking lances shall not be deformed.
Stack Wires as Shown
For 2--Wire Crimping
Wire Barrel
Contact Requirements
Insulation Barrel Formed
Around But Not Cutting
into Wire Insulation
Wire Barr el Seam Closed With
No Strands Protruding or Showing
0.50 [.020] Cutoff Tab
L
en
g
th
No Burrs on Cutoff Tab
Wire Strands and Insulation
Both Visibl e in This Area
EndofWireFlushWith
EndofWireBarrelor
0.88 [.035] (Max) Wire Length
0.10--0.51 [.004--.020] (Applicator)
0.10 [.004] Min (Hand Tool)
Rear Bellmouth
Front Bellmout h Visible
0.25 [.010] Max Flash
Locking Lances Not Deformed
Note: All r equirements apply to both pin
and socket contact.
Contact Stop Not
Crimped or Deformed
Locking Lances Not Deformed
Contact Stop Not
Crimped or Deformed
Figure 2 (Cont’d)