Datasheet

Modular Plugs, Accessories and Tooling
4
FEATURES AND BENEFITS
True mass displacement termination of jacketed cable with solid or stranded conductors
Available in all performance grades: CAT 6A, CAT 6, CAT 5E, CAT 5 and CAT 3
Meets or exceeds EIA/TIA and ISO industry performance and specifications
Various positions, number of contacts, housing styles and packaging options available
The most complete line of semiautomatic and manual termination
capabilities and tooling – low applied cost
Complete line of hand-held tooling available
Available for shielded and unshielded cable, round or flat oval, various cable diameters accommodated
Complete line of accessories such as boots and strain reliefs
Secure line of plugs available for secure or protected networks
Recognized by Underwriters Laboratories Inc, File # E81956
Certified by Canadian Standards Association Certificate No LR 7189A
SPECIFICATIONS
ELECTRICAL
Applications: 150 VAC max. at 1.5 A @ 25° C, derated to 0.2A @ 70° C
Dielectric Withstanding Voltage: 1000 Volts AC between contacts
1500 Volts AC all contacts connected together with shield
Insulation Resistance: 500 Megohms
MECHANICAL
Cable-to-Plug Tensile Strength: 17 lbs [76N] min.
Durability: 750 mating cycles
Temp. Rating: -40° C to +60° C
Flame Rating: UL 94V-0
ENVIRONMENTAL
Thermal Shock: IDC-wire interface and jack-plug interface
Humidity Temperature Cycling: IDC-wire interface
Humidity Steady State: Jack-plug interface
Mixed-Flow Gas
PRODUCT SPECIFICATION
108-1163 Standard
108-1163-2 High Performance
www.te.com/EnterpriseNetworks   +1-800-553-0938  Fax: 1-717-986-7406  5/14 318178AE