Datasheet

Datasheet Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
1
Power PCB Relay RT1
I
1 pole 12 / 16 A, 1 CO or 1 NO contact
I
DC- or AC-coil
I
Sensitive coil 400 mW
I
5 kV / 10 mm coil-contact, reinforced insulation
I
Ambient temperature 85°C (DC-coil)
I
WG version: Product in accordance to IEC60335-1
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0413
Applications
Boiler control, timers, garage door control, POS automation,
interface modules
F0144-B
Approvals
V
REG.-Nr. 6106,
Z E214025, B C0786, S 0039110/01-02, FFI 190164 A1,
H 98.4118.01
Technical data of approved types on request
Contact data
Contact configuration 1 CO or 1 NO contact
Contact set single contact
Type of interruption micro disconnection
Rated current 12 A 16 A
Rated voltage / max.switching voltage AC 240/400 VAC
Limiting continuous current UL: 20 A
Maximum breaking capacity AC 3000 VA 4000 VA
Limiting making capacity, max 4 s, df 10% 25 A 30 A
Contact material AgNi 90/10, AgNi 90/10 gold plated
Mechanical endurance DC coil > 30 x 10
6
cycles
AC coil > 10 x 10
6
cycles
Rated frequency of operation with / without load 6 / 1200 min
-1
Contact ratings
Type Load Cycles
RT314 16 A, 250 VAC, NO contact, 85°C, DF 10%, UL508 50x10
3
RT314 16 A, 250 VAC, NC contact, 70°C, 30min
-1
53x10
3
RT314 20 A, 250 VAC, NO contact, 85°C, UL508 6x10
3
RT314 1000 W incandescent lamp, 250 VAC 1.2x10
3
RT314 10 A, 250 VAC, cosϕ=0.6, CO contact, 70°C 200x10
3
RT314 5 A / 2 A, 250 VAC, cosϕ=1, motor, NO contact, 10min
-1
, 70°C 1.1x10
6
RT314 0.26 A / 0.01 A, 230 VAC, cosϕ=0.38, valve, NO contact, 25min
-1
7.6x10
6
RT314 Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508
RT314 1hp @ 240 VAC, 1/2hp @ 120 VAC, NO contact, UL508
RT314 AC15, 6 A, 250 VAC, NO and NC contact, 85°C, EN60947-5-1
RT314 DC13, 2 A / 24 VDC, 0.2 A / 250 VDC, NO and NC contact, 85°C, EN60947-5-1
Coil data
Rated coil voltage range DC coil 5...110 VDC
AC coil 24...230 VAC
Coil power DC coil typ 400 mW
AC coil typ 0.75 VA
Operative range 2
Coil insulation system according UL1446 class F

Summary of content (4 pages)