Datasheet
108-40000
4. QUALITY ASSURANCE PROVISIONS
4.1. Qualification Testing
A. Sam ple Selection
Connector housings and contacts shall be prepared in accordance with applicable Instruction
Sheets and shall be selected at random from current production. All test groups shall consist of a
minim um of 6 connectors. Five contact circuits in each connector shall be random ly selected and
identified, unless otherwise specified, these contacts shall be used for all m easurem ents.
B. Test Sequence
Qualification inspection shall be verified by testing sam ples as specified in Figure 2.
4.2. Requalification Testing
If changes affecting form, fit or function are m ade to the product or m anufacturing process, product
assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
4.3. Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. W hen
product failure occurs, corrective action shall be taken and sam ples resubmitted for qualification.
Testing to confirm corrective action is required before resubm ittal.
4.4. Quality Conformance Inspection
The applicable quality inspection plan will specify sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Rev D 5 of 6