Datasheet

114- 40005
Rev H6 of 9
Figure 4
All Contact Latching Ears Must
Be Latched into Cover
0.13 [.005] (Max) Gap
Between Housing and
Cover (Typ Both Ends)
No Air Gaps Between
Wire Insulation And
Adjacent Contacts
0.51 [.020]
Protrusion (Ref)
0.89 [.035]
(Max) Recess
Side View of Application
Conductor Strands Will Be
Exposed and Deformed on
Both Sides
All Conductor
Strands Must Be
Below Tapered
Transition
Typical Cross- Section
Termination Requirements
3.5. Accessories (Figure 5)
A. Strain Relief
Strain relief may be added to any application.
B. Keying Plugs
Keying plugs are designed to be hand inserted directly into the contact cavities. Corresponding pins must
be removed from the mating connector.
C. Pull Loops
Flexible pull loops may be permanently assembled. The loop is installed between the strain relief and the
cover in strain--relieved applications. An unattached, insertion type of pull tab is also available for
receptacles not employing strain relief.