Information

Product Specification
108-5262
Rev. C6 6 of 14
Para.
Test Items Requirements Procedures
No. of Pos.
Loading Force
N Max.
1 29
2 39
3 39
4 39
6 39
8 59
10 59
3.5.6
Double Lock Plate
Loading Force
12 59
Fix housing of the testing machine,
and insert locking plate in axial
direction by operating the head at a
rate of 100mm approx. a minute.
Measure the force required to
complete loading of locking plate.
3.5.7
Termination Resistance
(Low Level)
3mΩ max. (Initial)
10mΩ max. (Final)
Measure by applying closed circuit
current of 50mA max. at open circuit
voltage of 50mV max. to the mated
contact test circuit in housing.
Fig.2.
3.5.8
Termination Resistance
(Specified Current)
Millivolt Drop:
3mV/A max. (Initial)
10mV/A max. (Final)
Measure by applying 1A at 12V DC
to contacts in mated connectors, by
probing at 75mm apart from wire
crimp after temperature becomes
stabilized. (Probing at Y and Y’ in
Fig.2) Fig.2.
Termination Resistance (Low Level):
Termination resistance is obtained after deducting the millivolt drop of 150mm-long
wire used for termination.
Probing points Y and Y’ shall be pretreated by uniform soldering in order to
stabilize measurement reading during the test.
Fig.2 Measurement of Termination Resistance