108-2043
Test Description Requirem ent Procedure
Heat Cycling (Current Cycling). W ire Size Current (am peres)
(AW G) .110 Others
26 2 2
24 4 4
22 4 6
20 6 8
18 8 14
16 10 20
14 15 30
12 40
10 48
65°C m axim um tem perature rise.
Ä Tem perature rise between 24 and
500 cycles shall not exceed 15°C
on any conductor.
UL 310.
Subject sam ples to 500 current
cycles of 45 m inutes ON and 15
minutes OFF.
MECHANICAL
Pull Out (Crim p Tensile). W ire Size Tensile
(AW G) (Lbs m inim um)
26 4
24 6
22 10
20 16
Above values are less than
maxim um withdrawal force. See
Figure 2.
18 20
16 30
14 60
12 70
10 80
UL 310.
Apply a direct and gradual pull at a
rate of 1 inch per m inute, 1 m inute
hold at specified load.
Secureness of Insulation
(Unassembled).
No separation of the insulation from
the term inal body.
UL 310.
Subject unwired term inals to a 3
pound pull between the insulation
and term inal for 1 m inute.
Secureness of Insulation
(Assem bled).
No separation of the insulation from
the term inal body.
UL 310.
Subject wired term inals to a 6
pound pull between the insulation
and term inal for 1 m inute.
Engagem ent-Disengagement
(Engaging-Separating).
See Figure 2. UL 310.
Engage and disengage term inals
and tabs 6 tim es.
ENVIRONMENTAL
Heat Age, 136°C. Meet Dielectric W ithstanding
Voltage, Test Condition A; and
Secureness of Insulation
(assem bled and unassembled).
UL 310.
Subject term inals to 136°C for 7
days.
Heat Age/Hum idity. Meet Dielectric W ithstanding
Voltage, Test Condition A.
UL 310.
Subject unwired term inals to 100E C
for 7 days followed by 85% RH at
30E C for 24 hours.
Figure 1 (end)
Rev D 3 of 5