Datasheet
108-2043
Tab Size
(Plain Brass)
Term inal
Plating
Force (pounds)
First
Insertion
First
W ithdrawal
Sixth
W ithdrawal
Individual
(m ax)
Individual
(m ax)
Average
(m in)
Individual
(m in)
Average
(m in)
Individual
(m in)
.250
Tin
17 17 5 3 4 3
.205/.187 15 20 5 3 3 2
.110 12 14 3 2 2 1
Figure 2
Engagem ent and Disengagem ent Forces
3.6. Term inal Tests and Sequences
Test or Exam ination
Test Group (a)
1 2 3 4 5 6 7 8 9 10 11 12
Test Sequence (b)
Exam ination of Product 1 1 1 1 1 1 1 1 1 1 1 1
Dielectric W ithstanding Voltage,
Test Condition A
2 3 3(c)
Dielectric W ithstanding Voltage,
Test Condition C
2
Dielectric W ithstanding Voltage,
Receptacle, Tab Entry Position
2
Heating (Tem perature Rise) 2
Heat Cycling (Current Cycling) 3
Pull Out (Crim p Tensile) 3
Secureness of Insulation
(Unassembled)
2 3
Secureness of Insulation
(Assem bled)
2 3 3(c)
Engagem ent-Disengagement
(Engaging-Separating)
2
Heat Age, 136E C 2 2
Heat Age/Hum idity 2 2 2
(a) See paragraph 4.1.A.
NOTE
(b) Numbers indicate sequence in which tests are performed.
(c) Uncrimped terminals and wires in test groups 4 and 11 shall be conditioned in the
environments indicated. After conditioning, each sample is crimped to the appropriate
wire and the electrical or mechanical test is performed.
Figure 3