Datasheet
108-2043
4. QUALITY ASSURANCE PROVISIONS
4.1. Qualification Testing
A. Sam ple Selection
Term inals and tabs shall be prepared in accordance with applicable Instruction Sheets and shall
be selected at random from current production. Test groups 1, 2, 3 and 4 shall each consist of 20
samples of each wire size and term inal type per group. Test groups 5, 6, 7, 8, 9, 10, 11 and 12
shall each consist of 20 sam ples of each terminal type per group. All sam ples to be term inated
shall be crim ped to appropriate tin plated test conductors.
B. Test Sequence
Qualification inspection shall be verified by testing sam ples as specified in Figure 3.
C. Acceptance
1. Requirem ents put on the test sam ples, as indicated in the Requirem ents portion of Figure 1,
exist as either the upper or lower statistical tolerance lim it (95% confidence, 98% reliability).
All sam ples tested in accordance with this specification shall m eet the stated tolerance lim it.
2. Failures attributed to equipm ent, test setup or operator deficiencies shall not disqualify the
product. W hen product failure occurs, corrective action shall be taken and samples
resubm itted for qualification.
4.2. Quality Conformance Inspection
The applicable inspection plan will specify the sam pling acceptable quality level to be used. Dim ensional
and functional requirem ents shall be in accordance with the applicable product drawing and this
specification.
4.3. Certification
This product has been recognized under the Com ponent Recognition Program of Underwriters
Laboratories Inc., Electrical File Num ber E-66717 and certified by Canadian Standards Association File
Num bers LR-7189. Also, VDE Testing and Certification Institute, Reference No. 4751_1431_1047.
Figure 4 Figure 5
Metal Plate Test Fixture Tab, Receptacle Entry Position
Rev D 5 of 5