Datasheet

LIGHT-N-LOK Connectors
114-13207
Rev
C 5
of 7
Tyco Electronics Corporation
7. Apply optional approved flammability rated tape or clamp to organize the wire. See Figure 7.
Figure 7
Optional Tape or
Clamp May Be
Applied
8. If using Tyco Electronics complete assemblies, all the assembly work has been done. They are
factory wired and ready for installation.
3.5. Connector Mating
Align the polarized mating faces of the housings, and push the housings together. DO NOT force the housings
to mate. When fully mated, the housings must appear bottomed with each other and flush at the point of
engagement. An audible and tactile click will be heard and felt. See Figure 8.
Figure 8
Tape or Clamp
Receptacle
10 [.394] Max.
10 [.394] Max.
Plug
Tape or Clamp
3.6. Connector Unmating
To reduce risk of electrical shock, DISCONNECT the electrical supply before unmating the connectors.
To unmate the connectors, squeeze the release latches on either side of the plug housing and pull back until
both connectors separate from each other.
DANGER