Datasheet
114- 2157
Rev G 9 of 14
Figure 8
Detail A — Too Loose Detail B — Correct Detail C — Too Tight
Metal
Sleeve
Terminal, Splice, or
End Cap Insulation
Wire
Insulation
Cross-Section of Insulation Crimp at Wire End of Terminal, Splice, or End Cap
(Illustrations Represent Uppermost Wire Insulation Range of Terminal, Splice, or End Cap
(Thinner Wire Insulation May Appear Slightly Different, But Will Perform the Same, Refer to Figure 2)
3.7. Bend Allowance
Upward and downward bend of the terminated terminal, splice, or end cap must be within the tolerance
provided in Figure 9.
Figure 9
11
11
11
11
11
Terminal
Splice
11
Datum Line
Datum Line
Center of Splice
End Cap
11
11
Datum Line
Center of Crimp
Center of Crimp
3.8. Repair
Damaged or defective terminal, splice, or end cap must not be used. If damage is evident, the terminal, splice,
or end cap should be cut from the wire and replaced with a new one. Crimped terminals, splices, or end caps