Datasheet

12-2018, Rev.1218
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
AXICOM
Signal Relays
n
Standard telecom relay (ringing and test access)
n
Slim line 15x7.5mm (.590x.295”)
n
Max. switching current 5A
n
2 form C bifurcated contacts (2 changeover contacts, 2 CO)
n
Immersion cleanable
n
High sensitivity for low power consumption 140mW/ 70mW
n
Single coil version with surge voltage resistance between contact
and coil: 2.5kV (2/10μs) meets the Telcordia Requirement GR-1089,
1.5kV (10/160μs) meets FCC Part 68
Typical applications
Communications equipment linecard application (ringing and test access),
PABX, voice over IP, office equipment, measurement and control equipment,
automotive equipment as CAN bus, keyless entry, speaker switch, medical
equipment, consumer electronics, set top boxes, HiFi
Approvals
UL 508 File No. E 111441, UL 60950,
IEC/EN60950 IEC Ref. Cert. No. 327
Technical data of approved types on request
Contact Data
Contact arrangement 2 form C (CO)
Max. switching voltage 220VDC, 250VAC
Rated current 2A
Limiting continuous current, 85°C 2A
Switching Power 60W, 62.5VA
Contact material AgNi, gold-covered
Contact style bifurcated contact
Minimum switching voltage 100μV
Thermoelectrical potential <10µV
Initial contact resistance <50mΩ at 10mA, 20mV
Frequency of operation, without load 50 operations/s
Operate time typ. 2ms, max. 4ms
Set/reset time typ. 2ms, max. 4ms
Release time
without diode in parallel typ. 2ms, max. 4ms
with diode in parallel typ. 4ms, max. 6ms
Bounce time typ. 1ms, max. 3ms
Electrical endurance
at 12V / 10mA typ. 5x10
7
operations
at 6V / 100mA typ. 1x10
7
operations
at 60V / 500mA typ. 5x10
5
operations
at 30V / 1000mA typ. 1x10
6
operations
at 30V / 2000mA typ. 2x10
5
operations
Contact ratings, UL 110VDC / 0.3A - 33W
30VDC / 2.0A - 60W
120VAC / 0.5A - 60VA
240VAC / 0.25A -60VA
125VAC / 1A NO Side
125VDC / 0.5A NO Side
Mechanical endurance typ. 100x10
6
operations
Coil Data
Magnetic system polarized
Coil voltage range 2 to 24VDC
Max. coil temperature 125°C
Thermal resistance < 125K/W
Coil versions, monostable
Coil Rated Operate Limiting Release Coil Rated coil
code voltage voltage Voltage voltage resistance power
VDC VDC VDC VDC Ω±10% mW
008 3.00 2.25 6.50 0.30 64 140
016 4.00 3.00 8.70 0.40 114 140
011 4.50 3.38 9.80 0.45 145 140
001 5.00 3.75 10.90 0.50 178 140
002 6.00 4.50 13.00 0.60 257 140
006 9.00 6.75 19.60 0.90 578 140
003 12.00 9.00 26.15 1.20 1029 140
005* 24.00 18.00 52.30 2.40 4114 140
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
* Available only in standard coil configurations
P2 Relay V23079
DC current [A]
DC voltage [VDC]
Max. DC load breaking capacity
108-98002 Rev. E
All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 15
Telecom-, Signal and RF Relays
P2 V23079 Relay
AXICOM
Coil Operating Range
U
nom
= Nominal coil voltage
U
max.
= Upper limit of the operative range of
the coil voltage (limiting voltage) when coils are
continously energized
U
op. min.
= Lower limit of the operative range of
the coil voltage (reliable operate voltage)
For latching relays U
set min.
resp. U
reset min.
U
rel. min.
= Lower limit of the operative range of
the coil voltage (reliable release voltage)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
3.2
3.4
-40-30 -20-10 0102030405060708090 100 110 120 130 140
Coil Voltage [U/Unom]
Uop. min.
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
70 mW
Unom. nominal coil voltage
Ambient Temperature [°C]
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
-40-30 -20-10 0102030405060708090 100 110 120 130 140
Ambient Temperature [°C]
Coil Voltage [U/Unom]
140 mW
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Unom. nominal coil voltage
Uop. min.
Urel. min.
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
-40-30 -20-10 0102030405060708090 100 110 120 130 140
Ambient Temperature [°C]
Coil Voltage [U/Unom]
200 mW
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Unom. nominal coil voltage
Uop. min.
Urel. min.
Z