Power and Environmental Savings
OLS vs. Traditional LAN Architectures
Once the equipment energy consumption is totaled, the following
formula can be used to calculate cost savings for commercial
power between traditional copper/fiber and OLS:
Equipment wattage x 1.1 x 2/1000 = KW
KW x 8760 hrs per year = KWH
0.107€ (European Average cost per KWH) =
annual energy costs for the equipment
Copper Solution example (700 users)
MDF has a router, servers, an analog gateway and a LAN switch
Each floor is equipped with multiple LAN switches and gateways
Combined AMPS = 229
Combined Watts = 82,368
Combined BTU = 52,948
OLS Solution example (700 users)
MDF has the same level 3 WAN router, an Optical Line Terminal
(OLT), an edge router, and DC power distribution units
Each floor is equipped with low power consumption Optical Network
Terminals (ONTs) at each user and all other equipment is passive
Combined AMPS = 279
Combined Watts = 24,088
Combined BTU = 41,330
The results – copper solution uses 50 AMPS less than OLS, however:
OLS saves 58,280 watts over copper solution (70%)
OLS saves 11,618 BTUs (22%)
Annual energy cost for copper solution: 77,205€
Annual energy cost for OLS solution: 22,578€