Information

Insulation Strain Relief
Conductor
Insulation will be contained
within the confines of the
insulation strain relief as indicated
B Min.
A
Top of
Contact
Conductor
Bare wires will not be visible
beyond back of housing
Centerline of Conductor
Back of Housing
Bare wires
will not extend
above top of contact
Choose the appropriate MTA Connector from the MTA Catalog 82056.
Select the proper wire style and AWG for the chosen MTA Connector
(Refer to pages 70-74).
Choose the MTA Termination Tooling (Refer to pages 76-79).
Terminate the Wire-to-MTA Connector per Application Tooling Instruction Sheet.
Inspect the MTA Wire Termination per Application Specification, especially the wire
depth. See illustrations: 114-13072 MTA-50 Connectors, 114-1019 MTA-100
Connectors, 114-1020—MTA-156 Connectors, Posted Connector, Card Edge,
114-1048 MTA-156 Quad Connectors, 114-1031 MTA-100 Ribbon Cable
Connector Assembly, and 114-1032 MTA-156 Ribbon Cable Connector Assembly.
Adjust the Termination Tooling (if needed) per Tooling Instruction Sheet
(repeat the step above).
Connector AB
MTA-100
.069–.087 .040
[1.75-2.21] [1.02]
MTA-156
.090–.113 .060
[2.29-2.87] [1.52]
75
MTA Wire Termination
Flowchart
MTA Wire Termination Flowchart
MTA, CST-100 II, SL-156 and
AMP Economy Power (EP) Connectors
Catalog 82056 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 6-08 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 52-55-1106-0800 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 57-1-254-4444 UK: 44-208-420-8341