AMP INCORPORATED HARRISBURG, P4. 17105 INTRODUCTION This publication is intended for use by tool operators as an in-process inspection procedure for Intermittent clip applications. To assure a satisfactory level of quality during clip applications, ths toot operator should visually inspect every clip application and should perform nondestructive clip retention (tensile pull) taste, as described in the following procedural.
(2) CHECK POSITION BACK END, CF CLIP CLIP MUST NGT BOTTOM ON PANEL OR 4 CLEARANCE EQUAL TO—— 0 GREATER THAN INSULATION DIAMETER (FIRST CLIP ON POST) (ADDITIONAL FLIPS) CLIPS MAY SEAT ON EACH OTHER NOTE: WHEN USING AMP TERM POINT AUTOMATIC WIRING MACHINES, CHECK CLIFF POSITIONING FOR CONFORMANCE TO AMP PRODUCT SPECIFICATION 11528010, SLIPS MUST HOT OVERRIDE. 1416 (REF 131657 MIN, '\f\ | LAST CLIP ON POST) Figure 2 (3) PULL TEST o " 4,; TOOL ENGAGES.
The first five clip terminations applied by each operator on Avery shirt should be checked with AMP 3. CHECK CLIP RETENTION (PULL TEST) (1) CHECK TERMINATION STRIPED WIRE tuts BE nondestructive Pull Test Tool, Pant No. 89358-2. Also, whenever a reel of clips or a2 spool of wire is changed, 031" x 062" POST_ ;lslBNL‘E“ or when a clip splice is encountered, each operator INSTILLATION oL o NOT EXTEND should again pull test the first five terminations BETWEEN WIRE applied AND POST AT \ applier. CONTACT AREA .