Cov lus qhia

408-2363
Rev K
2 of 5
3.1. Double-Face Terminal or Splice
1. Open tool handles FULLY.
2. Place the foil between faces of the tab end of terminal or splice, and squeeze the faces together
manually. See Figure 3, Detail A.
3. Place the tab end and foil between the crimping dies as shown in Figure 3, Detail B. Make sure that
the tab end is completely covered by the dies. DO NOT place the wire barrel between the dies.
4. Close the tool handles until the ratchet releases, then allow handles to open freely.
CAUTION
DO NOT CONTINUE TO SQUEEZE THE TOOL HANDLES AFTER THE RATCHET RELEASES. Damage will occur to the
tool if the ratchet is forced against the stop pin.
WIRE SIZE RANGE
(AWG
HAND
TOOL
CRIMP HEAD
PENUMATIC TOOL 69010
PNEUMATIC TOOL 69005
22-16
69997
---
---
16-14
49935
300583
300454
12-10
49935
300583
300454
8
69355
38394
300454
Figure 2
5. Remove the crimped terminal or splice from the tool.
6. For long-tongued terminals, several crimps will be necessary. These crimps should overlap to ensure
that the entire tab end is crimped.
7. For terminals, crimp the wire barrel using the appropriate tooling (refer to Figure 2) according to the
instructions packaged with the tooling.
Figure 3
3.2. Flag Terminal
1. Open tool handles FULLY.
2. Place the tab end of the terminal between the crimping dies as shown in Figure 4, Detail A. Make sure
that the tab end is completely covered by the dies. DO NOT place the wire barrel between the dies.
3. Place the foil between faces of the tab end of terminal. See Figure 4, Detail B.
4. Close the tool handles until the ratchet releases, then allow handles to open freely.
CAUTION
DO NOT CONTINUE TO SQUEEZE THE TOOL HANDLES AFTER THE RATCHET RELEASES. Damage will occur to the
tool if the ratchet is forced against the stop pin.
5. Remove the crimped terminal from the tool.
Double-Face Terminal or Splice
Detail A
Detail B
Tab End
Foil
Wire Barrel Not
Between Dies
Tab End Completely
Covered by Dies
Downloaded from Arrow.com.Downloaded from Arrow.com.