Information

108-2184
4. QUALITY ASSURANCE PROVISIONS
4.1. Qualification Testing
A. Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. Specim ens shall consist of 2, 3 and 8 position
connectors with TE HDSF size 16 gold plated pin and socket contacts and 14, 16 and 18 AW G
GXL wire.
B. Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 3.
4.2. Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
4.3. Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 2. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubmittal.
4.4. Quality Conformance Inspection
The applicable quality inspection plan shall specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Rev B 6 of 6