Datasheet

Mini- Universal MATE- N- LOK Splash- Proof Sealed Connect ors 114- 13089
Rev B10 of 20 Tyco Electronics Corporation
The contact cavity containing the keying plug must be sealed using a wire seal. The wire seal must be installed
into the contact cavity at the wire end of the housing after the keying plug is installed. The wire seal must be
inserted flanged end (end opposite the throat) first, over the keying plug and into the contact cavity. For
optimum sealing performance, the wire seal must have at least two of the three flanges fully inserted into the
contact cavity. See Figure 8.
The wire seal can be installed over the keying plug and into the contact cavity manually or by using Insertion Tool
91002--1. Instruction for using the tool is provided on Instruction Sheet 408--7347.
If a keying plug is installed into a housing, the corresponding contact cavity of the mating connector must
contain a cavity plug seal.
Note: Cap Housing Shown, Requirements Equally Apply to Pin Header
Contact with Wire Seal
Cavity Plug Seal
Keying Plug
Wire Seal (For
Keying Plug)
Interface Seal
Wire End of
Cap Housing
Mating Face of
Plug Housing
Mating Face of
Cap Housing
Figure 8
Contact with Wire Seal
Installed into Contact Cavity
Interface Seal
Installed onto Plug Housing
Plug Housing
Cap Housing
Silo (6 Places
Shown, Ref)
Keying Plug with Wire Seal
Installed into Contact Cavity
Cavity Plug Seal
Installed into Contact Cavity
Cavity Plug Seal
Installed into Contact Cavity
Cavity Plug Seal
Installed into Contact Cavity
Wire End of
Plug Housing
NOTE
i