User manual

Locking Clip Contacts and Housings
114- 25006
Rev F 9 of 9Tyco Electronics Corporation
6. VISUAL AID
Figure 13 shows a typical application of Locking Clip 0.64--mm [.025--in.] Square Contacts and Housings. This
illustration should be used by production personnel to ensure a correctly applied product. Applications which
DO NOT appear correct should be inspected using the information in the preceding pages of this specification
and in the instructional material shipped with the product.
FIGURE 13. VISUAL AID
LOCKING LANCE
MUST BE LATCHED
REAR BELLMOUTH
MUST BE VISIBLE
WIRE BARREL SEAM MUST B E
CLOSED, WITH NO CONDUCTOR
STRANDS SHOWING
LOCKING LANCE MAY
NOT BE DEFORMED
WIRE MUST BE FLUSH WITH
END OF WIRE BARREL,
OR PROTRUDE SLIGHTLY
WIRE AND INSULATION MUST
BOTH BE VISIBLE BETWEEN WIRE
AND INSULATION BARRELS
WIRES MUST NOT
BE CONFINED
KEYING PLUG LATCH
MUST ENGAGE HOUSING