5.4 Insulation Crimp and Crimp for Single-Wire Seal
A Position of the single-wire seal on the wire
The end of the wire insulation must at least be 0.3mm and may extend not more than 0.6 mm beyond the front
face of the seal (see Fig. 2).
Fig. 2
B Crimping data for single-wire seals
The shape, width and reference value for the height of the crimp are shown in Table 1 and the Order Numbers
of the single-wire seals are listed in Table 2.
The crimp height is correctly adjusted if the crimp encloses the seal in the shape of a circle. It is recommended
that the crimp height tolerance on the basis of the extension of the collar of the seal by the wire be fully utilized.
C Position of the single-wire seal in the crimp
The collar of the single-wire seal must be visible in the window in the base of the crimp. At the most, it
may touch the edge of the crimp (see Fig. 3)
Fig. 3
D Visual inspection
After crimping, the single-wire seal may have no visible cuts or notches around the diameter of the
bunch. Only pressure points which cannot cause tearing or splitting of the seal in the long term are permitted.