5.5 Contact Area
After crimping, neither the cantilever spring with locking lances nor the contact body with collar for
secondary retention may be bent or deformed.
5.6 Shape and Positional Tolerances of the Crimped Contact (see Fig. 4)
A Parallelism
The base of the wire crimp or of the crimp for the single-wire seal must be parallel to the base of the contact
body within a tolerance of 0.25mm.
B Symmetry
The lateral offset of the crimp for the single-wire seal must lie within a tolerance of 0.2mm symmetrical to the
contact body.
The single-wire seal itself must lie within a vertical symmetry tolerance of 1mm.
Fig. 4