user manual

Page 6
INSTALLATION MANUAL
REMOTE VEHICLE STARTER
Module Side View
Jumper Selections
12
3
The jumpers control the output from the White wire on the 6- pin harness. This is a
30amp relayed output. To change the output of the wire access the jumpers by sliding
the plastic cover off the top of the case. Move the jumper to one of the following positions.
If the jumper is in position #1 the output on the white wire will be 2nd Starter
If the jumper is in position #2 the output on the white wire will be 2nd Accessory
If the jumper is in position #3 the output on the white wire will be 2nd Ignition*
Note: *The factory default setting of the selectable output jumper is position #3.
Output on White wire Jumper position
Second Starter Position 1
Second Accessory Position 2
Second Ignition Position 3
Jumpers
Not Available
Temperature Sensor Input
Note: If the Temperature Sensor is installed the Cold Start Mode will
operate by monitoring temperate. If the sensor is not installed the
Cold Start Mode will function as Timer Mode. The temperature
sensor can be installed under the hood strapped to the radiator
hose to monitor coolant temperature or left mounted under the
dash to monitor ambient air temperature.